Type
Indoor Unit
Outdoor Unit
Power Supply [V, Phase, Hz]
Cooling
Heating
Indoor
Outdoor
Breaker Size
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
Capacity
Total Input
COP
Dimensions
Weight [with Heater]
*
2
Air Volume (Lo-Mi2-Mi1-Hi)
External Static Pressure
Sound Level (Lo-Mi2-Mi1-Hi)
Dimensions
Weight
Air Volume (High)
Sound Level (High)
Diameter
Max. Length / Height
Rated
Rated
EEL Rank
Rated [with Heater]*
2
Rated [with Heater]*
2
EEL Rank
Height
Width
Depth
Height
Width
Depth
Cooling - Heating
1 phase / 3 phase
Gas / Liquid (
Cooling*
1
Heating
*
1
With the optional air protect guide, the operation at -15
o
C outdoor temperature is possible.
*
2
Figures in [ ] are for the indoor unit with a booster heater.
kW
kW
kW
kW
mm
mm
mm
kg
m
3
/min
Pa
dB(A)
mm
mm
mm
kg
m
3
/min
dB(A)
A
mm
m
o
C
o
C
Ceiling Suspended Type Specifications
HEAT PUMP
PCA-RP71GA / [PCH-P71GAH]
PUH-P71VHA / YHA
7.6
2.84
2.68
D
8.8 [10.73]
2.76 [4.69]
3.19
D
210
1,310
680
34 [36
14 - 15 - 16 - 18
0
37 - 39 - 41 - 43
943
950
330 + 30
93
55
49 - 50
32 / 16
VHA : 230V - Single - 50Hz - Outdoor power Supply
YHA : 400V - Three - 50Hz - Outdoor power Supply
15.88 / 9.52
50 / 50
-5* ~ +46
-11 ~ +24
Non-Inverter Heat Pump
PCH-P GAseries
67
PCA-RP100GA / [PCH-P100GAH]
PUH-P100VHA / YHA
9.8
3.55
2.76
D
11.5 [13.98]
3.45 [5.93]
3.33
C
270
1,310
680
37 [39.5
20 - 21 - 23 - 25
0
40 - 41 - 43 - 45
943
950
330 + 30
94
65
50 - 52
32 / 16
PCA-RP125GA / [PCH-P125GAH]
PUH-P125YHA
12.3
4.52
2.72
D
14.3 [17.06]
4.72 [7.48]
3.03
D
43 [46
27 - 30 - 32 - 34
0
41 - 43 - 45 - 46
1,350
950
330 + 30
131
100
50 - 52
25
PCA-RP140GA / [PCH-P140GAH]
PUH-P140YHA
14.2
5.44
2.61
D
17.0 [19.76]
5.22 [7.98]
3.26
C
45 [48
27 - 30 - 32 - 34
0
42 - 44 - 46 - 48
1,350
950
330
131
100
51 - 53
25
270
1,620
680
FIXED SPEED
Weekly
Timer
Lossnay
connection
Group
Control
M-NET
connection
Optional
SWING
ACO
Hot Start
Quiet
Self
Diagnosis
COMPO
Auto Restart
Drain
Lift UP
Optional
4 notch
Optional
AUTO
VANE
Booster
Heater
High efficiency
Check!
Indoor Unit
Remote Controller
Outdoor Unit
*optional
PUH-P71/100 PUH-P125/140
Ceiling Suspended Typee Specifications
Cooling Only
Type
Indoor Unit
Outdoor Unit
Power Supply [V, Phase, Hz]
PCA-RP71GA
PU-P71VHA / YHA
7.6
2.84
2.68
D
210
1,310
680
34
14 - 15 - 16 - 18
0
37 - 39 - 41 - 43
943
950
330 + 30
93
55
49 - 50
32 / 16
Non-Inverter Cooling Only
PC-P GAseries
Cooling
Indoor
Outdoor
Breaker Size
Ext. Piping
Guaranteed Operating Range [Outdoor]*
Capacity
Total Input
EER
Dimensions
Weight
Air Volume (Lo-Mi2-Mi1-Hi)
External Static Pressure
Sound Level (Lo-Mi2-Mi1-Hi)
Dimensions
Weight
Air Volume (High)
Sound Level (High)
Diameter
Max. Length / Height
Rated
Rated
EEL Rank
Height
Width
Depth
Height
Width
Depth
1phase / 3phase
Gas / Liquid (
* With the optional air protect guide, the operation at -15
o
C outdoor temperature is possible.
kW
kW
mm
mm
mm
kg
m
3
/min
Pa
dB(A)
mm
mm
mm
kg
m
3
/min
dB(A)
A
mm
m
o
C
PCA-RP100GA
PU-P100VHA / YHA
9.8
3.55
2.76
D
270
1,310
680
37
20 - 21 - 23 - 25
0
40 - 41 - 43 - 45
943
950
330 + 30
94
65
50 - 52
32 / 16
PCA-RP125GA
PU-P125YHA
12.3
4.52
2.72
D
43
27 - 30 - 32 - 34
0
41 - 43 - 45 - 46
1,350
950
330 + 30
131
100
50 - 52
25
PCA-RP140GA
PU-P140YHA
14.2
5.44
2.61
D
45
27 - 30 - 32 - 34
0
42 - 44 - 46 - 48
1,350
950
330 + 30
131
100
51 - 53
25
270
1,620
680
FIXED SPEED
68
VHA : 230V - Single - 50Hz - Outdoor power Supply
YHA : 400V - Three - 50Hz - Outdoor power Supply
15.88 / 9.52
50 / 50
'-5* ~ +46
AUTO
VANE
Quiet
4 notch
Self
Diagnosis
Lossnay
connection
Group
Control
COMPO
M-NET
connection
Optional
Auto Restart
Weekly
Timer
SWING
Check!
Drain
Lift UP
Optional
Indoor Unit
Remote Controller
Outdoor Unit
PU-P71/100 PU-P125/140
*optional