Mitsubishi Electronics MXZ-ANA Heat Pump User Manual


 
16
w The operation frequency in COOL mode is restricted the upper limit frequency after 1 hour as shown below for
dew prevention.
It is rated frequency or less.
1 hour
Time
Maximum
frequency
Upper limit
frequency
Rated frequency or less
Applied
model
MUZ-A09
Minimum
frequency
Maximum
frequency
Minimum
frequency
Maximum
frequency
32
COOL
HEAT(MUZ)
70 32 76
DRY
32
MUZ-A12
32
Minimum
frequency
73 32 71 32
57
Maximum
frequency
2-8. OPERATIONAL FREQUENCY CONTROL OF OUTDOOR UNIT
1. Outline
The operational frequency is as following:
First, the target operational frequency is set based on the difference between the room temperature and the set tem-
perature.
Second, the target operational frequency is regulated by discharge temperature protection, high pressure protection,
electric current protection and overload protection and also by the maximum/minimum frequency.
2. Maximum/minimum frequency in each operation mode.
MUZ-A17
MUY-A17
10
87
15
93 10
MUZ-A24
MUY-A24
15
110
15
108
15
68
MUZ-A15
MUY-A15
10
82
15
93
10
57
68
102
OBT16--1.qxp 06.3.29 11:20 AM Page 16