6
Outdoor model MUZ-GE25VA-
A1
MUZ-GE25VA-
A2
MUZ-GE25VAD MUZ-GE33VA
Power supply
Single phase, 230 V, 50 Hz
Capacity
Rated frequency (Min.-Max.)
Cooling
kW
2.5 (1.1 - 3.5) 3.3(1.4 - 3.9)
Heating
3.2 (1.3 - 4.5) 3.2 (1.3 - 4.1) 3.2 (1.3 - 4.5) 4.0 (1.4 - 4.8)
Breaker Capacity
A10
Electrical data
Power input 1 (Total)
Cooling
W
560 910
Heating
730 1,030
Running current 1
(Total)
Cooling
A
2.9 4.3
Heating
3.8 4.8
Power factor 1 (Total)
Cooling
%
84 92
Heating
84 93
Starting current 1 (Total)
A 3.8 4.8
Coef cient of performance
(COP) 1 (Total)
Cooling
4.46 3.63
Heating
4.38 3.88
Compressor
Model
KNB073FFDHC KNB073FKVHC KNB092FFAHC
Output
W 550 650
Current 1
Cooling
A
2.44 3.70
Heating
3.30 4.30
Refrigeration oil
(Model)
L 0.32 (NEO22) 0.36 (NEO22) 0.32 (NEO22)
Fan motor
Model
RC0J50-DB
Current 1
Cooling
A
0.24 0.31
Heating
0.27
Dimensions W × H × D
mm 800 × 550 × 285
Weight
kg 30
Special remarks
Dehumidi cation Cooling
L/h 0.2 0.6
Air ow 1
Cooling
High
m
3
/h
Med.
1,806 1,956
Low
1,170 1,806
Heating
High
2,106 2,130
Med.
1,806 1,956
Low
1,452 1,476
Sound level 1
Cooling
dB(A)
46 47
Heating
48
Fan speed
Cooling
High
rpm
Med.
740 800
Low
490 740
Heating
High
860 870
Med.
740 800
Low
600 610
Fan speed regulator
3
Refrigerant lling capacity
(R410A)
kg 0.80
NOTE: Test conditions are based on AS/NZS 3823.1.1.
Cooling: Indoor Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Outdoor Dry-bulb temperature 35°C Wet-bulb temperature (24°C)
Heating: Indoor Dry-bulb temperature 20°C Wet-bulb temperature 15.5°C
Outdoor Dry-bulb temperature 7°C Wet-bulb temperature 6°C
Refrigerant piping length (one way): 5 m
1 Measured under rated operating frequency.
SPECIFICATION
3
OBH532E