Mitsubishi Electronics MUZ-GE33VA Air Conditioner User Manual


 
32
NOTE: The above broken lines are for the heating operation without any frost and defrost operation.
0.8
0.9
1.0
1.1
1.2
1.3
-10-5 0 5 1015202530354045
Outdoor intake air Dry-bulb temperature (°C)
Input correction factors
26
24
22
20
18
Indoor intake air Wet-bulb
temperature( )
Total input (Cooling :
at Rated frequency
)
Indoor air Wet-bulb temperature
difference (°C)
8.6
7.9
7.1
6.4
5.7
5.0
MUZ-GE50VA
8.2
7.5
6.8
6.1
5.4
4.8
MUZ-GE50VA2
MUZ-GE50VAD
7.1
6.5
5.9
5.3
4.7
4.1
6.6
6.0
5.5
4.9
4.4
3.9
MUZ-GE35VA
MUZ-GE35VA2
MUZ-GE35VAD
8.7
8.0
7.2
6.5
5.7
5.0
MUZ-GE42VA
MUZ-GE42VAD
5.6
5.1
4.6
4.2
3.7
3.3
MUZ-GE25VA
MUZ-GE25VAD
8.7
8.0
7.2
6.5
5.7
5.0
MUZ-GE80VA
8.5
7.7
7.0
6.3
5.6
4.9
MUZ-GE80VA2
MUZ-GE80VAD
7.6
6.9
6.3
5.6
5.0
4.4
MUZ-GE71VA
MUZ-GE71VAD
7.9
7.2
6.5
5.8
5.2
4.6
MUZ-GE60VA
MUZ-GE60VAD
MUZ-GE33VA
Indoor air Dry-bulb temperature
difference (°C)
18.2
16.8
15.4
14.0
12.6
11.2
9.8
8.4
7.0
5.6
22.7
21.0
19.2
17.5
15.7
14.0
12.2
10.5
8.7
7.0
26.2
24.1
22.1
20.1
18.1
16.1
14.1
12.1
10.1
8.0
20.0
18.5
16.9
15.4
13.9
12.3
10.8
9.2
7.7
6.2
23.8
21.9
20.1
18.3
16.4
14.6
12.8
11.0
9.1
7.3
26.4
24.4
22.3
20.3
18.3
16.2
14.2
12.2
10.2
8.1
MUZ-GE50VA
MUZ-GE50VA2
MUZ-GE50VAD
MUZ-GE33VA
MUZ-GE35VA
MUZ-GE35VA2
MUZ-GE35VAD
27.0
24.9
22.8
20.7
18.7
16.6
14.5
12.4
10.4
8.3
MUZ-GE42VA
MUZ-GE42VAD
MUZ-GE25VA
MUZ-GE25VAD
Outdoor intake air Wet-bulb temperature (°C)
-20 -15 -10 -5 0 5 10 15
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
Heating capacity (
at Rated frequency)
Capacity correction factor
15
20
26
MUZ-GE80VA
MUZ-GE80VA2
MUZ-GE80VAD
MUZ-GE71VA
MUZ-GE71VAD
MUZ-GE60VA
MUZ-GE60VAD
Indoor intake air Dry-bulb temperature ( )
Indoor air Dry-bulb temperature
difference (°C)
18.2
16.8
15.4
14.0
12.6
11.2
9.8
8.4
7.0
5.6
22.7
21.0
19.2
17.5
15.7
14.0
12.2
10.5
8.7
7.0
MUZ-GE50VA
MUZ-GE50VA2
MUZ-GE50VAD
27.0
24.9
22.8
20.7
18.7
16.6
14.5
12.4
10.4
8.3
MUZ-GE42VA
MUZ-GE42VAD
MUZ-GE25VA
MUZ-GE25VAD
26.2
24.1
22.1
20.1
18.1
16.1
14.1
12.1
10.1
8.0
MUZ-GE80VA
MUZ-GE80VA2
MUZ-GE80VAD
MUZ-GE71VA
MUZ-GE71VAD
MUZ-GE60VA
MUZ-GE60VAD
20.0
18.5
16.9
15.4
13.9
12.3
10.8
9.2
7.7
6.2
23.8
21.9
20.1
18.3
16.4
14.6
12.8
11.0
9.1
7.3
26.4
24.4
22.3
20.3
18.3
16.2
14.2
12.2
10.2
8.1
MUZ-GE33VA
MUZ-GE35VA
MUZ-GE35VA2
MUZ-GE35VAD
Outdoor intake air Wet-bulb temperature (°C)
-20 -15 -10 -5 0 5 10 15
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
Total input (Heating :
at Rated frequency
)
Input correction factor
15
20
26
Indoor intake air Dry-bulb temperature ( )
OBH532E