S
series
40
Two-way Floor Standing and Ceiling suspended Type Specifications
Type
Model Name
Indoor Unit
Outdoor Unit
Power Supply [V, Phase, Hz, Source]
MCF-GA35VB
MCF-GA35VB
MUCF-GA35VB
3.5
-
1.16
3.02
B
34 - 40 - 44
49
11.3
-
-
-
-
-
-
-
-
8.2
56
650
1,100
180
25
540
780
255
36
6.35 / 12.7
25 / 10
+21 ~ +43
-
MCF-GA50VB
MCF-GA50VB
MUCF-GA50VB
4.8
-
1.81
2.65
D
36 - 41 - 46
52
13.0
-
-
-
-
-
-
-
-
13.0
66
650
1,100
180
25
605
850
290
44
6.35 / 12.7
25 / 10
+21 ~ +43
-
MCF-GA60VB
MCF-GA60VB
MUCF-GA60VB
6.0
-
2.45
2.45
E
42 - 45 - 48
53
14.0
-
-
-
-
-
-
-
-
16.7
80
650
1,100
180
25
605
850
290
60
6.35 / 15.88
25 / 10
+21 ~ +43
-
Fixed-Speed Cooling Only
MCF-GAseries
Cooling
Heating
Max. Running Current
Indoor
Outdoor
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
SPL
Air Volume
Capacity
Total Input
COP
SPL
Air Volume
Input
Dimensions
Weight
Dimensions
Weight
Diameter
Max. Length / Max. Height
Rated
Min - Max
Rated
EEL Rank
IN [Low-Mid-High]
OUT
IN [High]
Rated
Min - Max
Rated
EEL Rank
IN [Low-Mid-High]
OUT
IN [High]
Rated
Height
Width
Depth
Height
Width
Depth
Liquid / Gas (
Cooling
Heating
kW
kW
kW
dB(A)
dB(A)
m
3
/min
kW
kW
kW
dB(A)
dB(A)
m
3
/min
A
W
mm
mm
mm
kg
mm
mm
mm
kg
mm
m
o
C
o
C
230, Single, 50, indoor/outdoor separate power supply
Cooling Only
MUCF-GA35VB MUCF-GA50/60VB
39
Econo Cool
AUTO
VANE
Auto Restart
Self
Diagnosis
Flare
connection
24-hour Timer
25m
10m
I FEEL
Deodorizing
Optional
Air-Cleaning
Optional
HORIZONTAL
SWING
Outdoor Unit
Indoor Unit
Remote