Mitsubishi Electronics 30 Air Conditioner User Manual


 
7
PLH18AK PLH24AK PLH30AK PLH36AK PLH42AK
18,000 24,000 30,000 35,400 42,000
19,000 [24,500/25,500] 26,000 [31,500/32,500] 33,000 [39,500/41,200] 38,000 [45,900/47,600] 44,300 [52,200/53,900]
11,000 [16,500/17,500] 16,500 [22,000/23,000] 18,500 [25,000/26,700] 23,000 [30,900/32,600] 26,800 [34,700/36,400]
1.75 2.57 3.17 3.63 3.98
1.59 [3.19/3.49] 2.51 [4.11/4.41] 3.04 [4.94/5.44] 3.45 [5.75/6.25] 3.82 [6.12/6.62]
1.32 [2.92/3.22] 2.15 [3.75/4.05] 2.55 [4.45/4.95] 2.93 [5.23/5.73] 3.24 [5.54/6.04]
10.5 10.3 10.4 10.0 10.7
7.2 7.0 6.9 7.1 7.0
PLH18AK PLH24AK PLH30AK PLH36AK PLH42AK
Munsell 0.7Y 8.59/0.97
208/230, 1, 60
20 25
15 17
0.7 1.2 1.4
7.7/8.3 [1.6/1.9] 9.1/10.4 [1.9/2.4] 11.1/12.2 [2.3/2.8]
530-710 710-990 780-1060
490-670 670-950 740-1020
33-1/16
33-1/16
10-3/16 11-3/4
37-3/8
37-3/8
1-3/16
57 71 75
11
PUH18EK PUH24EK PUH30EK PUH36EK PUH42EK7
Munsell 5Y 7/1
208/230, 1, 60
20 30 40
16 20 22 28
0.75 0.65+0.65 0.75+0.75 0.8+0.8
RH247NAB NH33NBD NH41NAD NH47NAD ZR42K3-PFV
12.0 11.5 14.0 17.5 20.4
37 54 73 87 109
0.11/0.17 (23/28) 0.16/0.17 (33/39)
Capillary tube
Reverse cycle
34-1/4 38-3/16
11-5/8 13-9/16
33-1/2 49-9/16
131 202 245 246 246
With grille
Indoor unit-remote controller DC12V, Indoor unit- outdoor unit DC12V
Cooling *1 BTU/h
Capacity Heating *1,*3 BTU/h
Heating *2,*3 BTU/h
Cooling *1 kW
Heating *1,*3 kW
Heating *2,*3 kW
SEER
HSPF
INDOOR UNIT MODELS
External finish
Power supply V, Phase, Hz
Max. fuse size (time delay) A
Min. ampacity A
Fan motor F. L. A.
Auxiliary heater A (kW)
Airflow Dry CFM
Lo-Hi Wet CFM
Win
Dimensions D in
Hin
Win
Dimensions
Din
(GRILLE)
Hin
Weight lbs
Weight (GRILLE) lbs
OUTDOOR UNIT MODELS
External finish
Power supply V, Phase, Hz
Max. fuse size (time delay) A
Min. ampacity A
Fan motor F. L. A.
Models
Compressor
R. L. A.
L. R. A.
Crankcase heater A (W)
Refrigerant control
Defrost method
Win
Dimensions D in
Hin
Weight lbs
REMOTE CONTROLLER
Control voltage
(by built-in transformer)
Item
Models
Power
consumption
NOTES: *1 Rating conditions (cooling) indoor: 80°F DB. 67°F WB outdoor: 95°F DB. 75°F WB
(heating) indoor: 70°F DB. 60°F WB outdoor: 47°F DB. 43°F WB
*2 Rating conditions (heating) indoor: 70°F DB. 60°F WB outdoor: 17°F DB. 15°F WB
*3 Heating capacity and power consumption in [ ] include auxiliary electric heater operation at 208/230V.
Units should be installed by licensed electric contractor accordingly to local code requirement.
* Specifications subject to change without notice.
5. Specifications