Miele S184 Vacuum Cleaner User Manual


 
8
J) CHANGING FILTERS
TROUBLE SHOOTING GUIDE
Before returning the vacuum cleaner to a Miele Service Center, check the
following items:
Problem
Check Point Cause / Remedy
Motor doesnt run.
(no noise is heard at all)
Motor runs but no suction.
Beater bar does not rotate.
Cord connection.
Hose inlet clogged.
Check the bag change indicator.
Dust bag broken or clogged.
Central filter.
Beater bar selector.
Beater bar / housing.
Belt broken or loose.
Plug cord into outlet correctly.
I If there is a clog, remove it.
If it shows full, replace the dust
bag.
If the dust bag is broken, replace it.
If the central filter is full of dust, clean
or replace it.
Select the correct position.
If there is an obstruction, remove it.
Replace the belt.
In addition to the dust bag, the vacuum cleaner
contains two filters; a central filter that protects the
motor (fig.1) and a HEPA filter that removes
particles from the exhausted air (fig.2). The HEPA
filter should be changed every six months or
whenever it becomes dirty. The central filter should
be changed or rinsed out whenever the HEPA filter
is replaced.
CENTRAL FILTER (Fig. 1)
Part # F0391100
To remove, slide the central filter forward out of its
housing.
IMPORTANT: If the central filter has been rinsed
out, make sure it is dry before re-installing it.
HEPA FILTER (Fig. 2)
Part # S02Z6000
To change the HEPA filter.
1) Remove the exhaust cover.
2) Take out the HEPA filter and replace with a new
one.
IMPORTANT: Do not forget to re-install the filters before use.
Fig. 1