Meyer 526 Furnace User Manual


 
15
INSTALLATION
GENERAL REQUIREMENTS
CAUTION:
EQUIPMENT MUST BE INSTALLED BY A QUALIFIED
HEATING PERSON.
CAUTION:
ONLY “CLASS A” ALL-FUEL OR SOLID FUEL CHIM
-
NEYS INTENDED FOR USE WITH YOUR WOOD
-
CHUCK SHOULD BE USED.
FIRST AND ABOVE ALL is safety for you and your
family.
MUST USE: Class A Masonry or ULC listed, manufac
-
tured Class A All Fuels Chimney.
RECOMMENDED SIZE: Rectangular 8"x12" or Round
8".
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE. The Woodchuck is
to be used in conjunction with a listed gas or oil fired
furnace or as a central furnace.
ELECTRICAL SUPPLY: 115 volts, 60HZ, 1 Phase,
less than 12 amps.
Install system with 0.2 static pressure.
Flue setting .06 W.C. Max to .04 W.C. Min.
Wood or coal related fires are caused almost exclu
-
sively by installation, operation or maintenance errors;
but not by unsafe equipment.
IMPORTANT: Check with your local state and federal
codes on installation at your local fire department.
PLACEMENT AND MINIMUM CLEAR
-
ANCES
CAUTION:
FURNACE MUST BE INSTALLED ON A NON-COM
-
BUSTIBLE FLOOR OR 3/8" THICK FIREPROOF MILL
-
BOARD OR EQUIVALENT.
Locating your unit is very important for proper draft and
most efficient heating possible. See figure 7.
FIGURE 7 LOCATING THE WOODCHUCK