Maytag HE31250T Water Heater User Manual


 
Instructions for Installation (cont'd)
Installation Checklist
1. Whether or not the element conversion is made, the model
rating plate must be marked. Using a hard point ink pen, HOT ___._[_ _ COLD
check the appropriate block within the model rating plate, .
which is located adjacent to the lower access panel.
2. Is the fuse or circuit breaker size correct as shown in the
chart in the "Product Specifications" section?
CONDUIT_ v J_
3. Are the wires from the circuit breaker or fuse service to the _ TEMPERATURE-
water heater's junction box on the correct wire size (gauge) as _ J PRE!;URE
RELIEI
shown in the chart in the "Product Specifications" section? q
/
4. Is the new temperature-pressure relief valve properly
installed, and piped to an adequate drain? See
"Temperature-Pressure Refief Valve" in the "Instructions --DISCHARG
(Donot cIpor
for Installation" section, plug
5. Is the water heater completely fdled with water? See
"Filling the Water Heater" instructions in the "Instructions
for Installation" section.
6. Will a water leak damage anything? See "Locating the /
New Water Heater" in the "Instructions for Installation" [ - ['-'-
section. _ 6"AIRG¢
7. Are the cold and hot water fines connected to the water x_ _" _
i
r
heater correctly? See "Water Piping" instructions in the _ FLOORDRAIN
"Instructions for Installation" section.
8. Is there adequate clearance for maintenance around the
water heater?
ELEC'FRICWATERHEATER _o
m ogwmwcm_ _ Ik1"rAl.LE¢
9. Do you need to call your electric company to check your ,_,,_,_ _ (_
wiring? I I
] I I I
® Maytsgisa Tr=:bonerk of_ Co'potationand
ksusedI_ L_ toS_ Irl_str k_, Inc
MODEL RATING PLATE
17