Troubleshooting
Start Up Conditions
THERMAL EXPANSION Smelly water may be eliminated or reduced in some waterheater
models by replacingthe anode(s)with one of less activematerial,
Water supply systems may, because of such events as high line and then chlorinating the waterheater tank and allhot water
pressure, frequent cut-offs, the effects of water hammer fines.Call Maytag Customer Service at 1-800-788-8899 for an
among others, have installed devices such as pressure reducing authorized servicerfor furtherinformation concerningan Anode
valves, check valves, back flow preventers, etc...to control Replacement Kit #66001068 and this Chlorination Treatment.
these types of problems. When these devices are not equipped
with an internal by-pass, and no other measures are taken, the If the smelly water persists afterthe anode replacement and chlo-
devices cause the water system to be closed. As water is heat- rination treatment, we can only suggest that continuous chlorina-
ed, it expands (thermal expansion) and closed systems do not tion and filtering conditioning equipment be considered to elimi-
allow for the expansion of heated water, nate the water problem.
The water within the water heater tank expands as it is heated Do not remove the anode leaving the tank unprotected. By
and increases the pressure of the water system. If the relieving doing so, all warranty on the water heater tank is voided.
point of the water heater's temperature-pressure reliefvalve is
reached, the valve will relieve the excess pressure. The temper- "AIR" IN HOT WATER FAUCETS
ature-pressure relief valve is not intended forthe constant
relief of thermal expansion. This is an unacceptable condition _,WARNING
and must be corrected.
HYDROGEN GAS: Hydrogen gas can be produced in
a hot water system that has not been used for a
It is recommended that any devices installed which could create long period of time (generally two weeks or more).
a closed system, have a by-pass and/or the system have an Hydrogen gas is extremely flammable and explo-
expansion tank to relieve the pressure built by thermal expan- sive. To prevent the possibility of injury under these
sion in the water system. Expansion tanks are available for conditions, we recommend the hot water faucet be
opened for several minutes at the kitchen sink
ordering through the Maytag Customer Service. Contact the before any electrical appliances which are connect-
local water supplier and/or call Maytag Customer Service at ed to the hot water system are used (such as a dish-
1-800-788-8899 for an authorized servicer for assistance in washer or washing machine). If hydrogen gas is pre-
sent, there will probably be an unusual sound mmi-
controlling these situations, lar to air escaping through the pipe as the hot
water faucet is opened. There must be no smoking
STRANGE SOUNDS or open flame near the faucet at the time it is open.
Possible noises due to expansion and contraction of some RUMBLING NOISE
metal parts during periods of heat-up and cool-down do not
represent harmful or dangerous conditions. In some water areas, scale or mineral deposits will build up on
your heating elements. This buildup will cause a rumbling
Operational Conditions noise. Foliow"Element Cleaning/Replacement"instructions
to clean and replace the elements.
SMELLY WATER
HIGH TEMPERATURE SHUT OFF SYSTEM
In each glasslined water heater there is installed at least one anode
rod (seeparts section) for corrosion protection of the tank. The water heater has a high limit shut offsystem with a reset
Certain water conditions will cause a reaction between this rod button located on the thermostat.
and the water. The most common complaint associated with the
anode rod is one of a "rotten egg smell". This odor is derived from Follow the resetting instructions which refer to the high limit
hydrogen sulfide gas dissolved in the water.The smell is the result behind the access panel.
of four factors which must all bepresent for the odor to develop:
a. a concentration of sulfate in the supply water. NOTE: Ifyour water heater is connected to an "OFF
b. little or no dissolved oxygen in the water. PEAK" clock, and uses the "3wire lead" wiring diagram in
c. a sulfate reducing bacteria within the water heater. (This the "Wiring Diagram" section, then the water heater will
harmless bacteria is non-toxic to humans.) have a hi-limit on both the upper and lower thermostats.
d. an excess of active hydrogen in the tank. This is caused by Follow the instructions to reset the hi-limlt behind the
the corrosion protective action of the anode, upper and lower access panels.
25