Master Lock B100CEH Air Conditioner User Manual


 
23
105398
OWNER’S MANUAL
Output Rating (kw/Btu/Hr) 10 (35,000) 20 (70,000) 30 (100,000) 44 (150,000)
Fuel Use Only Kerosene or No. 1 Fuel Oil
Fuel Tank Capacity
(Liters/U.S. Gal.) 11.4/3.0 18.9/5.0 34/9.0 51.1/13.5
Fuel Consumption
(Liters Per Hr./Gal. Per Hr.) 1.1/.28 1.97/.52 3.0/.79 4.1/1.1
Electric Requirements 230 V/50 Hz (Same All Models)
Amperage (Normal Run) .8 1.0 1.2 1.2
Hot Air Output (CMM/CFM) 4/140 6.4/225 12/425 14.2/500
RPM 1425 2850 2850 2850
SPECIFICATIONS
WIRING DIAGRAM
(7)
(2)(1)
(8)
(3) (4) (6)
(N)
(5)
1a
1
1b
Power Plug
230 V/50Hz
Ignition Control
Green-Yellow
Green-Yellow
Ignitor
Photocell
White
White
Red
Brown
Brown
Blue
Blue
Blue
Blue
ON/Off Switch
Black
Black
Motor