Master Lock ATS 211 Garage Door Opener User Manual


 
Limit and Force Adjustment Control
Weather conditions may cause some minor
changes in door operation requiring some re-
adjustments, particularly during the first year of
operation.
Pages 21 and 22 refer to the limit and force
adjustments. Only a screwdriver is required. Follow
the instructions carefully.
Repeat the safety reverse test (page 23) after any
adjustment of limits or force.
Maintenance Schedule
Once a Month
• Manually operate door. If it is unbalanced or
binding, call for professional garage door service.
• Check to be sure door opens and closes fully.
Adjust limits and/or force if necessary. (See pages
21 and 22.)
• Repeat the safety reverse test. Make any
necessary adjustments. (See page 23.)
Twice a Year
• Check chain tension. Adjust if necessary.
Once a Year
• Oil door rollers, bearings and hinges.
The opener does not require additional
lubrication.
Do not grease the door tracks.
24
Force ControlsLimit Controls
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of severe injury or death to persons:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Do not permit children either to operate or to play with the opener. Keep a remote control in a
location inaccessible to children.
3. Operate opener only when the door is in full view and free from any obstruction. Keep the door in
sight until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
4. Check safety reversal system monthly. See page 23. The garage door
MUST
reverse on contact
with a 2x4 board laid flat on the floor. If an adjustment is made to either the force or the limit of
travel, both adjustments may be needed and the safety reversal system must be checked.
Failure
to properly adjust the opener may result in severe injury or death.
5. If possible, use the manual release only when the door is in a closed position. Caution should be
taken whenever the disconnect cord is actuated with the door open.
Weak or broken springs may
cause the door to fall rapidly, causing injury or death to persons.
6. KEEP GARAGE DOORS PROPERLY BALANCED. See page 3.
An improperly balanced door could
result in severe injury or death.
Repairs to cables, spring assemblies and other hardware must be
made by a qualified person.
7. Disconnect the electric power from the garage door opener before making any repairs or removing
the covers.
8. SAVE THESE INSTRUCTIONS.
Adjustment Label
Adjustment Label
(Located on the left side panel)
(Located on the back panel)
KG
KG
1
3
9
7
5
1
3
9
7
5
WARNING
WARNING
Do not exceed 8 complete cycles of door operation per hour in commercial applications.
Care of Your Opener