Master Lock ATS 211 Garage Door Opener User Manual


 
Installation Step 6
Install the Door Control
13
Children operating or playing with a garage
door opener can injure themselves or others.
The garage door could close and cause
serious injury or death.
Install the Door Control (or any additional push
buttons) out of the reach of children and away
from all moving parts of the door and door
hardware,
but where the garage door is visible.
Do not allow children to operate the push
button(s) or the remote control transmitter(s).
A moving garage door could injure someone
under it.
Activate the opener only when the
door is properly adjusted, you can see it
clearly, and there are no obstructions to door
travel.
• Strip 1/4" of insulation from one end of the bell
wire; connect the wire to the two screw terminals
on the back of the Door Control by color, white to
2, and white/red to 1.
• Locate the door control within sight of the door at a
minimum height of 5 feet where small children
cannot reach, and away from all moving parts of
the door and door hardware. Fasten the Door
Control Button securely with 6ABx1-1/2" screws. If
installing into drywall, drill 5/32" holes and use the
anchors provided.
• Run the bell wire up the wall and across the ceiling
to the opener. Use insulated staples to secure the
wire in several places. Be careful not to pierce the
wire with a staple, thereby resulting in a short.
• Receiver terminal screws and the antenna are
located on the back panel of the opener. Position
the antenna wire as shown.
• Then connect the bell wire by color to the opener
terminal screws: white to 2 and white/red to 1.
Remember to affix the User Safety Instruction
label to the wall near the door control, and the
Maintenance Instruction Label in a prominent
location on the inside of the garage door.
If the label adhesive will not adhere to your garage
wall surface (or becomes loose with time), use tacks
to secure the label alongside the door control.
Page 25 explains how to operate the opener using
the door control.
Do NOT connect the power and operate the
opener at this time.
The trolley will travel to the
full
open
position but will not return to the
close
position until the sensor beam is
connected and properly aligned.
See Safety Reversing Sensor Instructions
beginnning on page 16.
Outside Keylock Accessory Connections
To opener terminal screws:
white to 2 and white/red to 1
WARNING
Opener
Terminal
Screws
Lighted
Door Control
Button
2-Conductor
Bell Wire
Antenna
Back Panel
of Opener
KG
KG
M.D.C. CERT. NO.
1
3
9
7
5
132C2105-1
WARNING: To reduce the risk of severe injury
or death by entrapment, when adjusting either
the force or limits of travel controls ensure that
the door reverses on a 1 inch object (or a 2 x 4
board laid flat). See instructions for proper
adjustment procedure.
This device complies
with FCC Rules Part
15. Operation of this
device is subject to the
following conditions:
1. This device may
not cause harmful
interference. 2. This
device must accept
any interference
that may be received,
including interference
that may cause
undesired operation.
PART NO: Nº DE PIÈCE:
D.O.C. CERT. NO.
DATE:
Sears Roebuck & Co.
Sears Canada Inc., Toronto
Assembled in Mexico - Assemblé du Mexique
PAT. #RE29,525; 4,750,201; 4,806,930 Other Patents Pending.
AVERTISSEMENT: Pour réduire les risques de
blessures mortelles par happement, après tout
réglage de la force de déclenchement ou des
seuils de fin de course s'assurer que le sens de
la course s'inverse lorsque la porte entre en
contact avec un object de 13 mm (1 po) de
hauteur (ou un madrier de 2 x 4 de section, à
plat) posé sur le sol. Effectuer les reglages
selon les procédures décrites dans la notice.
1
3
9
7
5
2 3
TO PROGRAM RECEIVER CODE
FOR EACH REMOTE CONTROL
1. Press and HOLD remote control
transmitter push button.
2. Press receiver code button. The opener
light will flash once.
3. Release transmnitter button. Opener
has learned code.
TO ERASE ALL RECEIVER CODES
1. Press and HOLD receiver code button.
Green indicator light alongside will turn
ON.
2. When light turns OFF (about 6
seconds) ALL codes are erased from
opener memory.
1
Lighted
Door Control
Terminal Screws
2-Conductor
Bell Wire
WHT
RED
-2
-1
Dry Wall Anchors
Insulated Staples
6ABx1-1/2" Screw
Lighted Door Control Button
Hardware Shown Actual Size