Master Lock ATS 211 Garage Door Opener User Manual


 
1/4-20x1-1/2"
Hex Bolt
"C" Wrap
Wire
Sensor
Wing Nut
Invisible Light Beam
Protection Area
Sensor
Sensor
Connect Wire to
Opener Terminals
Bell Wire
Bell Wire
Finished
Ceiling
Indicator Light
Sensor
Connections
Wall Control
Connections
(dotted line)
OPENER TERMINAL SCREWS
1
2 3
Run paired wires from both sensors to the opener.
Use insulated staples to secure wire to wall and
ceiling.
• Strip 1/4" of insulation from each set of wires.
Separate white and white/black wires sufficiently to
connect to the opener terminal screws: white to 2
and white/black to 3.
Plug in the opener. Green indicator lights in both
the sending and receiving eyes will
glow steadily
if
wiring connections and alignment are correct.
If the indicator light is
off
in the
receiving eye
(and
the invisible light beam path is not obstructed),
alignment is required.
• Loosen the receiving eye wing nut to allow slight
rotation of unit. Adjust sensor vertically and
horizontally until the green indicator light
glows
with a steady light
.
• When indicator lights are
glowing steadily
in both
units, tighten the wing nut in the receiving eye unit.
18
Push connector in
until you hear a click
Tab should be
flush with back
of connector
• Insert the wire connector into each
sensor and push until you hear a
click (Figure 6). The white tab on the
sensor should be flush with the back
of the connector.
Wire Connector
White Tab
Safety Sensor
1/4-20x1-1/2"
Hex Bolt
Wing Nut
Hardware Shown Actual Size
Center each sensor unit in a "C" wrap with lenses
pointing toward each other across the door.
• Secure sensors with the hardware shown. Finger
tighten the wing nut on the
receiving eye
to allow
for final adjustment. Securely tighten the
sending
eye
wing nut.
Figure 6
Figure 7
Trouble Shooting
1. If the
sending eye
indicator light does not
glow
steadily
after installation, check for:
• Electric power to the opener.
• A short in the white or white/black wires. These
can occur under staples or at screw terminal
connections.
• Incorrect wiring between sensors and opener.
• An open wire (wire break).
2. If the sending eye indicator light
glows steadily
but
the receiving eye indicator light doesn't:
• Check alignment.
• Check for an open wire to the receiving eye.