Martin Fireplaces 53D9042 Indoor Fireplace User Manual


 
16
53D9042. Rev 1 03/03
CHIMNEY CAP INSTALLATION
M
ODEL LC CHIMNEY CAP
SPECIAL NOTE: The proper height as previously explained is important to assure proper draft and safety. The
chimney cap extends the flue outlet four inches above the top of the last section of chimney. This should be
kept in mind when determining the proper height for the chimney. The chimney should not be extended more
than 90 inches above the supporting roof structure without additional support. In the case of an “A” frame type
construction or other steep pitch roofs that require more than 90 inches of chimney above the roof, a support
should be attached to the chimney at the 90 inch level that is strong enough to support a wind load of 3-1/8
pounds for each inch the chimney extends above 90 inches. The flue outlet must be a minimum of three feet
above the point where in penetrates the roof.
C
AUTION: Be careful to avoid electrical shock hazard when contacting wires to the metal chimney components.
1. Extend the regular chimney sections until the top of the chimney is 4 inches below the total flue height
desired. Do not snap the last section of inlet air duct or largest diameter pipe in place until Step 3 is
completed.
2. Remove the shingles from around the chimney so that the flashing may be installed, with the upper part of
the flashing under the shingles.
3. Set the flashing on the roof. Hold a section of the outside pipe (13" diameter) on the flashing and scribe a
line around the flashing, then cut the top off the flashing by cutting 1/4 inch below the scribed line. This
should increase the diameter of the flashing outlet sufficiently to allow the flashing to be placed over the
chimney. See Figure 21.
4. Snap the last section of inlet air duct in place and slide the flashing over the chimney. Adjust the chimney
to assure that the proper minimum clearances are maintained.
5. Nail the flashing securely in place with eight nails.
6. Seal the crack between the top of the flashing and the chimney with mastic. Leave some excess mastic at
this area to be used in step eight.
NOTE: Use pliers and wear gloves when performing step seven to minimize the danger of cutting your
hands on the edge of the storm collar.
7. Place the storm collar around the chimney and put the collar together like a belt in belt loops. Slide the end
of collar under the two loops on the other end with the loops facing up. Overlap the ends of the collar until
it is tight against the chimney. Bend the free end of the collar back over the loops to hold the storm collar
securely together. The excess end of the storm collar may be trimmed off.
8. Slide the storm collar down snugly against the flashing until the excess mastic left in step six is forced up
into the crack between the storm collar and the chimney. This should make the joint between the flashing
and the chimney watertight.