Marquis DVT-38 Indoor Fireplace User Manual


 
Marquis 38 8
CLEARANCE TO COMBUSTIBLES
CLEARANCES TO COMBUSTIBLES
BACK 0” to stand-offs
SIDES 0” to stand-offs
TOP 0” to stand-offs
BOTTOM 0”
ADJACENT SIDE WALL 1” to side of faceplate
MANTLE see diagram
VENT 1” to outside side and bottom surface,
2” to outside top surface.
PRECAUTIONS
This appliance must be installed by a qualified gas installer and the installation must
conform to the installation codes.
Provide adequate clearance around air openings of the appliance. Never obstruct front
openings.
Provide adequate clearances for proper operation and servicing of the appliance.
This appliance must be properly connected to a venting system.
Combustible mantle allowed in shaded
area. Mantle extension maybe increased
1” (25mm) for each additional 1” (25mm)
increase in clearance height.
Minimum Height From Top Surround: 6”
Minimum Height From Bottom of Appliance: 37”
NOTE: Low profile wooden crowns and mold-
ings above the unit are not
considered as mantles. I.E. 1” or less protrusions
on the upper mantle facing are acceptable
6” (152 mm)