Lopi Liberty Wood Stove Stove User Manual


 
Listing Information 31
© Travis Industries 100-01164 4041115
Listing Label
LISTED SOLID FUEL BURNING APPLIANCE
SUITABLE FOR USE IN RESIDENTIAL, ALCOVE
AND MOBILE HOME INSTALLATIONS.
PREVENT HOUSE FIRES - Install and use only in accordance with the Lopi Liberty (520-NT) owner’s manual. Contact your
local building or fire officials about restrictions and installation inspection in your area. Refer to local building codes and
the chimney manufacturer’s instructions for precautions required for passing a chimney through a combustible wall or ceil-
ing. Do not run a chimney connector through a combustible wall or ceiling. Do not connect this unit to a chimney flue serv-
ing another appliance. Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or
other means approved by local building or fire officials.
DO NOT REMOVE THIS LABEL
STANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6” diameter, minimum 24 MSG black or 25 MSG
blued steel connector, with listed (type HT) factory-built chimney, suitable for use with solid fuels or masonry chimney.
Pedestal or legs are required.
ALCOVE INSTALLATIONS REQUIRE: One of the listed doublewall connectors shown below. Pedestal or legs are required.
Maximum alcove depth 48”, minimum alcove height 84”.
MOBILE HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the listed doublewall connectors shown
below. In addition, mobile home installations require outside air - use the optional pedestal or outside air boot. Pedestal or
legs are required.
DURAVENT model DVL with DURA-PLUS chimney
AMERI-TEC model DCC with model HS chimney
SECURITY model DP with SECURITY model ASHT or S2100 chimney
METALFAB model DW connector with TG chimney
Standard Masonry Chimney with any one of the above listed connectors
TESTED TO RELEVANT PORTIONS OF
UL 1482, 737 AND 907.
SERIAL
NUMBER
FREESTANDING INSTALLATION
CLEARANCES AND
FLOOR PROTECTION
REQUIREMENTS:
A. SIDEWALL TO UNIT
B. BACKWALL TO UNIT
C. CORNER TO UNIT
D. SIDEWALL TO CONNECTOR
E. BACKWALL TO CONNECTOR
F. CORNERWALL TO CONNECTOR
STANDARD RESIDENTIAL
INSTALLATION (SINGLEWALL
CONNECTOR)
16”
15”
9.5”
28”
18.25”
21”
MOBILE HOME, ALCOVE AND
REDUCED CLEARANCE INSTALLATIONS
(REQUIRES DOUBLE WALL CONNECTOR)
16”
10”
7.5”
27.5”
12.75”
18.5”
STOVE
FLOOR PROTECTOR
6"
MIN.
6" MIN.
16" MIN.
45û
STO
V
E
ADJACENT WALL
ADJACENT WALL
F
C
STOVE
BACKWALL
SIDEWALL
E
D
B
A
MINIMUM CLEARANCES TO COMBUSTIBLES:
OPTIONAL EQUIPMENT: Rear blower (electrical rating: 115V,
60 Hz., 1.8 Amps)
4800 Harbour Pointe Blvd. SW Mukilteo,
W
By:
2004 2005 2006 Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec.
For use with solid wood fuels only (cord wood). Operate with
feed door closed - open to feed fire only. Do not use a grate
or elevate fire - build fire directly on the hearth.
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with July 1990 particulate emission standards.
DATE OF MANUFACTURE
Manufactured by:
MODEL:
LIBERTY (520-NT)
Replace glass only with LOPI supplied NEOCERAM ceramic
glass (5mm).
0210IGN