Linear DVS-1200 Home Security System User Manual


 
34
CALL LIMITER
The factory setting for the call limiter is OFF. This
allows the communicator to report burglary alarms,
once for each sensor, as many times as they are
triggered.
STEP #101 The Console can be programmed to only allow fi ve
burglary reports total per arming period using this
step.
NOTE: Sensors programmed for 24-hour functions
(Emergency, Panic, Fire) always send a Central
Station report and always sound the local siren
regardless of the Call Limiter setting.
DIALING DELAY
The factory setting will cause the communicator to
dial the Central Station instantly when an alarm or
supervisory event occurs.
STEP #103 The communicator can be programmed to wait 30
seconds before dialing using this step. This gives
the user time to disarm the system and prevent
communications in the case of a subscriber
generated false alarm.
DIALING METHOD
The factory setting causes the communicator to
dial using DTMF (dual-tone multi-frequency) tone
dialing.
STEP #104 The communicator can be programmed to use
pulse (rotary) dialing using this step. Use this option
if the telephone line in the installation does not
support tone dialing.
0
1
HOME
AWAY
0 FOR OFF (UNLIMITED)
1 FOR ON (5 VIOLATIONS)
PROGRAMMING STEP #101
PROGRAM
STORE PROGRAM
1
0
3
DEF
HOME
AWAY
0 FOR NO DELAY
1 FOR 15 SECOND DELAY
PROGRAMMING STEP #103
PROGRAM
STORE PROGRAM
1
0
4
GHI
HOME
AWAY
0 FOR TONE DIALING
1 FOR PULSE DAILING
PROGRAMMING STEP #104
PROGRAM
STORE PROGRAM
1