10
TELEPHONE LINE CONNECTION
✦ Connect the Console to the telephone line if the
system is monitored, requires 2-way audio, or
requires telephone remote command.
✦ Telephone RING & TIP terminals are for connection
to the incoming telephone line.
✦ Seized telephone ring & tip are for connection
to local telephone sets. When the communicator
activates, all the local telephone sets will be
disconnected to prevent an off-hook telephone on
the premises from blocking the communicator call.
1. Install a USOC RJ31-X or RJ38-X jack to the
telephone system near the Console.
2. Route an appropriate modular telephone line cord
from the jack to the Console.
3. Route the line cord through the Console’s wiring
access hole.
4. Connect the incoming telephone line wires to the
Console's telephone terminal block TIP and RING
terminals.
5. Connect the local telephone set wires to the
Console’s telephone terminal block SEIZED TIP
and SEIZED RING terminals.
✦ When directly connecting (without a telephone line)
to the DVS-1200 with the RA-2400 remote access
software (Version 1.3 or later), disconnect the incoming
telephone line and connect the modem to the panel's
TIP and RING terminals (with the modem's red & green
phone line wires). Press the EMERGENCY key while
in Test Mode to cause the panel to connect to the
modem.
AUTOMATION OUTPUT CONNECTION (OPTIONAL)
✦ The Console provides a Automation Output to
control lights, devices and appliances.
✦ Automation Output can connect to most popular
home automation devices and other simple
electronic devices (see fi gure).
✦ Press
to turn the Automation Output on, press
again to turn it off.
Programmable Options
✦ There are many programmable options for the
Automation Output.
✦ The Automation Output can be programmed for a
variety of useful functions, such as: fl ashing during
alarm, fl ashing after an alarm, on while armed, or,
on during exit/entry delays.
✦ See the “Advanced Programming” section of this
manual for details on changing the function of the
Automation Output.
OPTIONAL
VOICE MODULE
MODEL: VB-2
TELEPHONE
TERMINAL
BLOCK
LINEAR SECURITY CONSOLE MODEL DVS-1200
TELEPHONE TERMINAL BLOCK
R
T
R1
T1
TO PHONE
LINE
RING
TIP
TO LOCAL
PHONES
SEIZED TIP
SEIZED RING
SEIZED
RING (R1)
SEIZED
TIP (T1)
LINE
RING (R)
LINE
TIP (T)
GRAY
RED
T
R
T1
R1
13245
6
7
8
TO LOCAL
TELEPHONE
SETS
TO TELEPHONE
NETWORK
8-POSITION
USOC RJ31-X
(OR RJ38-X)
JACK
T
R
R1
T1
SHORTING BAR
SHORT REMOVED
ON PLUG
INSERTION
8-PIN
MODULAR
PHONE CORD
DVS-1200
TELEPHONE
TERMINAL
BLOCK
GREEN
BROWN
BLUE, ORANGE
BLACK, AND
YELLOW NOT
USED
CONNECT TELEPHONE LINE
TO THE TELEPHONE
TERMINAL BLOCK
AC
AC
EXT. SPKR
(-)
H/A -
H/A +
RELAY N.O.
RELAY DRY
MAIN TERMINAL BLOCK
OPTIONAL
VOICE MODULE
MODEL: VB-2
MAIN
TERMINAL
BLOCK
LINEAR SECURITY CONSOLE MODEL DVS-1200
LIGHT EMITTING
DIODE (L.E.D.)
MINUS H/A TERMINAL WILL SWITCH
TO GROUND WHEN AUTOMATION
OUTPUT IS ACTIVATED
POSITIVE H/A TERMINAL PROVIDES
+12 VOLTS DC AND IS CURRENT
LIMITED AT 30 MILLIAMPS MAXIMUM
X-10
BURGLAR ALARM
INTERFACE
(CAN CONTROL
HOUSE LIGHTS
THROUGH X-10
SYSTEM)
X-10
LINEAR RB-90
RELAY MODULE
YOUR
LOAD
POWER
SOURCE
LIGHT
EMITTING
DIODE
(L.E.D.)
EXAMPLE AUTOMATION OUTPUT HOOK-UPS
H/A + H/A -
H/A + H/A - H/A + H/A -