Lincoln Electric IM438-B Fan User Manual


 
A-11
INSTALLATION
MAGNUM COOLER 10-I & 20-I
A-11
K529-10 POWER INPUT CABLE WITH WATER AND
GAS LINES
The K529 power input cable connects from the front of
a Lincoln power source to the back of LN-7 and LN-7
GMA wire feeders equipped with a water solenoid
control. K529-10 is 10 ft. (3.0m) long and includes two
water hoses and a gas line. The lengths of the two
water hoses and gas line are designed for proper con-
nection to a Magnum Cooler and a gas cylinder locat-
ed on the back of a Lincoln K874, K840-1*, K841-1* or
K842-1* double cylinder undercarriage. The water
connections are 5/8-18 left hand thread while the gas
connection is 5/8-18 right hand thread. Reference
Figure 8 when using the K529 power input cable.
* Not available at time of printing.
Figure 8
K529-10 POWER INPUT CABLE CONNECTION
SHIELDING
GAS
COOLANT
OUT
WITHOUT
SOLENOID CONNECTIONS
COOLANT
COOLANT
GUN CABLE
IN
OUT
K529-XX
COOLANT
COOLANT
ELECTRODE CABLE
TO WORK
CONTROL CABLE
COOLANT
IN
NOTE:
BLUE HOSE
RED HOSE
=
COOLANT
OUT
COOLANT
IN
=