17 Room Air Conditioner
6. Shroud
1. Remove the fan. (Refer to section 21)
2. Remove the screw that fastens the shroud.
3. Remove the shroud. (See Figure 24)
4. Re-install the component by referring to the
removal procedure, above.
7. Motor
1. Remove the cabinet. (Refer to section 18)
2. Remove the cover control and disconnect a wire
housing in control box. (Refer to section 19)
3. Remove the blower. (Refer to section 21)
4. Remove the fan. (Refer to section 22)
5. Remove the 4 screws which fasten the motor.
(See Figure. 25)
6. Remove the motor.
7. Re-install the components by referring to the
removal procedure, above.
8. Compressor
1. Remove the cabinet. (Refer to section 18)
2. Discharge the refrigerant system using Freon
TM
Recovery System.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before venting
the Freon
TM
. Leave the valve in place after
servicing the system.
3. Disconnect the 3 leads from the compressor.
4. After purging the unit completely, unbrace the suc-
tion and discharge tubes at the compressor con-
nections.
5. Remove the 3 nuts and the 3 washers which fas-
ten the compressor.
6. Remove the compressor. (See Figure 26)
7. Re-instill the components by referring to the
removal procedure, above.
Disassembly
Electrical Parts
Figure 24
Figure 25
Figure 26