9. Voltage of Connectors according to Indoor Fan Speed
- 51 -
4
3
2
1
1 1
4
3
1 2 3 4
2 3 4 5 62
INDOOR
FAN
MOTOR
INDOOR PWB ASSY
Connecting wires
between Indoor
and Outdoor
Indoor
Connecting Terminal
Outdoor
Connecting Terminal
Input Power
POWER
TRANS
CN-POWER CN-TRANS
CN-DC/DC
RY-COMP
BK
BL BK BR RD
BK BL
BL
BK
BR
RD
+-
12
32
42
12
32
42
12
32
42
OUTDOO
R CN-DC/DC
INDOOR
CN-DC/DC
INDOOR
CN-MOTOR
No. of pins
MODELS
CONNELTORS
S-Hi Hi Med Low Off
32.0 27.8 24.1 21.2 0.0
5.0 5.0 5.0 5.0 5.0
0~5 0~5 0~5 0~5 5.0
0~12 0~12 0~12 0~12 0~12
17.0 17.0 17.0 17.0 17.0
32.0 27.8 24.1 21.2 0.0
0~12 0~12 0~12 0~12 0~12
17.0 17.0 17.0 17.0 17.0
32.3 28.1 24.4 21.3 0.0
18K
DC Voltage(±10%)