LG Electronics AS-W126URH0/UBH0/UWH0/UMH0/UCH0 Air Conditioner User Manual


 
Service Manual 41
Operation
1. Sleep timer operation for cooling cycle
While in cooling mode operation, 30 min. later since the start of the sleep timer, the setting temperature
increase by 1°C. After another 30min. elapse, it increases by 1°C again.
2. Sleep timer operation for heating cycle
While in heating mode operation, 60 min. later since the start of the sleep timer, the setting temperature
decrease by 1°C. After another 60min. elapse, it decreases by 1°C again.
Setting temp. (˚C)
1.0˚C up
1.0˚C up
Cooling ON temp.
(Setting temp. +0.5˚C)
Cooling OFF temp.
(Setting temp. -0.5˚C)
0.5 1 Sleep time
(
hr
)
Setting temp. (°C)
Heating ON temp.
(Setting temp)
Heating OFF temp.
(Setting temp. +3.0°C)
1 2 Sleep time
(
hr
)
1.0°C down
1.0°C down
When the sleep time is reached after [1,2,3,4,5,6,7hr] is input by the remote control during the operation, the
operation of the appliance stops.
When the appliance is on pause, the sleep timer mode cannot be input.
Sleep timer operation