HIGH PRESSURE
DRAWING TITLE: MODEL UNIT:
DWG NO.:
SCALE: N/A
SHEET: 1 OF 1
DRAWN BY: 06-19-07
CHRISTOPHER FERRARA
DECRIPTIONS:
06-19-07
06-19-07
06-19-07
SAL NEGRO
CHRISTOPHER FERRARA
JOHN PARDINI
CHECKED:
ENGINEER:
APPROVED:
MOTORIZED AUTO-FLUSH & DRAIN
-
LG 10-30(PARTS LEGEND) LG (H)(MAFD)
321-010-030-000210
This drawing and all information therein are the property of Electro-Steam Generator Corp. and shall not be disclosed,
in whole or in part, to any third party without prior permission of Electro-Steam Generator Corp.
19
20
1.) Control Panel
2.) ON/OFF Switch
3.) Manual Low-Water Reset (MLWR) (Optional)
5.) Water Level Probes
6.) Water Inlet - 3/8" Y-Strainer
7.) 3/8" Water Solenoid
8.) 1/4 HP Pump & Motor
9.) 1/2" Check Valves
10.) 5/8" x 6 1/4" Sight Glass (Seismic Optional)
11.) Water Barrier - 1/2" U-Tube
12.) 0-90 PSI Pressure Controls
13.) Reset on "Safety" Pressure Switch
14.) 1/4" Needle Valve
15.) 0-160 PSI Pressure Gauge
16.) Steam Out - 1/2" Ball Valve
17.) 1/2" Vacuum Relief Valve
18.) Safety Relief Valve
19.) Manual Drain - 3/4" Ball Valve
20.) Motorized Auto-Flush & Drain (MAFD) (Optional)
21.) 5 PSI (NC) Pressure Switch for (MAFD)
PARTS LEGEND - LG (H)(MAFD)
SIDE VIEW
TOP VIEW
1
5
12
14
15
6
CONTROL
5 PSI
SAFETY
CONTROL SAFETY
13
3
2
6
7
7
8
8
9
10
10
11
16
16
17
17
18
18
19
20
21
1
2
21 of 33