NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
9
Position The Groove At The Bottom Of
Log (A) Over The Grate And Slide It
Forward Against The Grate Here
Figure 9
READ LOG WARNINGS ON PAGE 9 BEFORE PROCEEDING
1. Remove front glass enclosure panel from appliance.
a. Open Control Compartment Access Panel (see Control Compart-
ment Access Instructions on Page 4.
b. Remove the glass panel enclosure (see Removing Glass Enclosure
Panel instructions on Page 9.
2. Remove the following from fi rebox; log set, embers (rockwool) and
vermiculite. Handle logs carefully to prevent breakage.
3. Ensure the Grate is properly installed in the fi rebox with the 4 legs
of the grate fi tting into the 4 dimples on the fi rebox fl oor.
4. Install Vermiculite - Place some vermiculite on the fi rebox fl oor around
the grate (the entire bag of vermiculite will NOT be used). See Figure 15
on Page 13. DO NOT PLACE ANY VERMICULITE ON THE BURNER.
6. Placement of Glowing Embers -
Separate the Embers (rockwool) into pieces about the size of a quarter
(see Figure 7 ). Keep the pieces fl uffed up, not matted. Distribute
these pieces over the surface of the burner, as shown in Figure 8.
Do not use more than is necessary. Ensure that the main burner ports
remain uncovered by the ember material.
Note: This appliance is provided with enough Glowing Embers for
several applications, do not use all that is in a new bag at one time. For
best glowing effect, replace the ember material annually. Replacement
Glowing Embers are available (order Catalog Number 88L53).
B
C
D
A
(Valve Access Side)
(Valve Access Side)
(Valve Access Side)
(Valve Access Side)
Position Groove At The Bottom Of
Log (A) Over The Log Support Here
8. Place Log (B) as shown in Figure 10.
Position Log (B) Against The Back Of
The Grate Here
Position Groove at The Bottom Of Log (B) Over The Grate
Here And Slide It Against The Back Of The Grate
Figure 10
Log (C) Lays Over Logs (A) and (B)
A
B
Position And Slide Log (D) Against The
Back Of
The Grate
Place Log (D) Over The
Flat Spot On Log (A)
Here
A
Position The Groove in The Back of Log (C)
Against The Grate
Figure 11
9. Place Log (C) as shown in Figure 11.
Figure 12
10. Place Log (D) as shown in Figure 12.
Figure 8
Place Embers on burner as shown.
DO NOT PLACE EMBERS OVER
GAS PORTS / AREAS CIRCLED
7. Place Log (A) on the grate as shown in Figure 9