Lennox Hearth MPE-36R Indoor Fireplace User Manual


 
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
10
WIRING DIAGRAM - 120 VOLT
Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to
the appliance on the left side.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER
AND DANGEROUS APPLIANCE OPERATION.
SWITCH WIRING - 120 VOLT
Figure 19
Figure 20
L1 = BLACK (POWER)
L2 = BLACK (POWER)
G = GREEN (GROUND)
N = WHITE (COMMON)
N1 = WHITE (COMMON)
N2 = WHITE (COMMON)
HOME POWER
SUPPLY
120 V AC.
HOME POWER SUPPLY
120 V AC.
FIREPLACE WIRE
HARNESS
See Power Supply Specifi cations on Page 3.
P
P-TRA.
N-LIGHT
POWER-N
N-FAN
N-M
SIP13
SIP11
SIP7
T-P
Transformer
Control Panel
Flame / Ember
On/Off Switch
SIP3
SIP2
SIP4
TEM.
SIP6
K-H
K-P
REMOTE
N-FLAME
L-FLAME
Circuit
Board
Remote Sensor
Temperature Sensor
Control Panel
(power on/off)
Control Panel
Heater On/Off
Switch
Relay 1
Relay 2
L-R1
L-R2
L-FAN
Heater 1 (L)
Heater 2 (L)
Fan Motor (L)
Flame Motor (L)
Light (L)
GROUND
t104° C t90°C
MAIN POWER
L1
L
L2
N1
N2
N
N
Wall Thermostat
Wall Switch
(power on/off)
Outside Switches
L-M
P-L
L-LIGHT
GROUND
SIP13
N
L1
GROUND
YELLOW AND GREEN
ORANGE
BLACK
BLUE
BLUE
WHITE
N
L1
N1
N2
L2
120 V 1600W
120 V AC
GROUND