Lennox Hearth RDV33 Indoor Fireplace User Manual


 
17
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Maintenance & Servicing
maintenanCe CheCklist
The following should only be performed by a qualified
service technician.
Caution: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after
servicing.
1. Annual inspection should be made and the following
checks performed:
oWhen unit is cool, remove glass and inspect burner for
dirt, soot, and lint accumulations, and remove if neces
-
sary. If excessive soot accumulation is present on burner,
have a qualified service technician adjust the burner for
proper combustion.
oClean inside of glass with gas fireplace glass cleaner.
NEVER attempt to remove or clean the glass when the
unit is hot.
oCheck the hot air outlet vents for lint or other accumula-
tions. Never block or restrict vent openings, obstruct flow
of ventilation air, or use vents other than those approved
for use with the Ravenna gas insert.
oCheck that the chimney and its outlet are open and free
of soot, blockage, or debris.
oCheck gaskets once a year. Gaskets must be tight. Replace
if necessary.
oInspect the pilot system for proper flame. NEVER ADJUST
THE PILOT until after the gas pressure has been checked
and the supply lines have been completely bled (this may
take an hour or more when bleeding through the pilot).
All pilots are checked and burned at the factory prior to
shipment. The pilot adjustment screw is located below the
ON/OFF/PILOT control knob. Remove the pilot adjusting
cover with a flat-bladed screwdriver to access the pilot
adjusting screw. Adjust the pilot screw to properly size the
flames. The flames should directly contact the thermopile
and extend across the main burner ports. Be careful not
to back the screw out of its threads. Replace the cover
and check for gas leaks using a gas leak test solution.
oCheck that the area around the insert is kept clear and is
free of combustible materials, gasoline, and other flam
-
mable vapors and liquids.
oCheck the millivolt system as per the table on this page.
2. The viewing glass should be cleaned periodically (see
Glass Maintenance).
glass door Cleaning and maintenanCe
Cleaning: When cool, the glass may be cleaned with a clean,
soft cloth and Windex. For cleaning white condensation from
the interior glass, use KEL KEM gas fireplace glass cleaner
available from your insert dealer. Use of caustic or abrasive
cleaners may damage the glass. DO NOT operate the insert
with broken glass. DO NOT clean door or glass when hot. DO
NOT abuse the glass door by striking or slamming it shut.
DO NOT use substitute materials if replacing the glass. DO
NOT spray commercial glass cleaner with ammonia on the
door and glass gasket as it may dissolve the gasket glue.
Glass Replacement: The glass in the insert door cannot be
replaced separately. Should the glass be damaged, the entire
glass, gasket, and metal frame assembly must be replaced
as a unit. This replacement glass assembly is available from
your Lennox Hearth Products dealer. The glass is neo-ceramic
and alternative types must not be used.
WARNING: Do not operate appliance with the glass panel
removed, cracked, or broken. Do not remove glass door
while the insert is hot. Replacement of the glass door
should be done by a qualified service technician.
Millivolt and System Checks
Check
Test
To
Test
Connect
Meter
Leads to
Terminals
Thermostat
Connects
Meter
Reading
Should Be
A Complete
System
2 & 3
Closed 100 MV
or More
B Thermopile
Output
1 & 2 Open Greater
Than
325 MV
C System
Resistance
2 & 3 Closed 2.5 Ohms
proper pilot flame appearanCe
Figure 19