Kompernass KH 1150 Fan User Manual


 
- 5 -
1Fasten the installation plate (L) to the ceiling with 2 screws and, using the
pegs if necessary.
Test the bearing capacity of the screw connection.
2 Hang the fan in the installation plate, making sure that the mount lines
up properly with the notch (see Fig., circle).
3 Electrical connection.
ƽ
DANGER
:
The electrical connection may only be performed by a qualified
electrician!
Failure to follow these instructions presents a life-threatening risk
of electric shock!
L
Colour coding:
Green-yellow (I): PE conductor
Blue (II): Neutral conductor
Brown (III): Current-carrying wire (also: black)
Connect the electrical wires
Step 1: Connect the PE conductor to the lamp-wire connector (I).
Step 2: Connect the blue wire (N) (II).
Step 3: Connect the brown wire (L) (III).
Connect the cable plug
Connect the cable plugs of the two PE conductors of the fan with the
sockets on the installation plate.
Then connect the wide cable plug of the fan to the socket on the installation
plate.
4 Snap the casing (A) onto the installation plate: insert it into the two adjacent
bearings and snap it into the opposing spring-loaded bearing (click!).
5 Insert the halogen bulbs into the lamp holders: Place the bulbs with light
pressure into the round recesses and then turn them clockwise until securely
fitted.
6 Switch on the power supply.
NOTE:
Avoid touching the halogen bulbs with your fingers. Use a clean
cloth or cloth gloves when inserting the bulbs.
“KLICK”
A
(I)
(II)
(III)
1
2
3
IB_KH1150_E2679_LB4 31.01.2008 8:41 Uhr Seite 5