Kohler k-10950 Plumbing Product User Manual


 
Troubleshooting Guide (cont.)
Symptoms Probable
Causes
Recommended Action
E. There is
water
leakage on
electrical
components
or
connectors.
E. Remove the spout and check
for corrosion on connections
between AC unit to solenoid
and the solenoid to sensor. If
possible clean terminals. If you
are unable to repair the
connection, order a new battery
assembly or sensor assembly, as
required. The origin of the leak
must be investigated and
repaired.
F. The AC
unit does
not work.
F. Measure the voltage of the unit.
The voltage should measure 6
Volts. If there is no power or
low power is detected, order a
new unit.
3. No water
flow (Either
AC or DC).
A. Sensor
eyes are
dirty.
A. Wipe the sensor eyes with a
damp soft cloth. Wipe dry with
a dry soft cloth.
B. Water not
turned on.
B. Verify that the water supply is
turned on and that pressure is
at least 20 psi (137 kPa).
C. Incorrect
installation.
C. Verify that the faucet is
mounted flat to the deck
surface and that the sensor eyes
are aligned to the user area.
Ensure that the sensor eyes are
above the rim of the lavatory.
Refer to the installation
instructions.
D. The
filter(s) are
plugged.
D. Turn off the water supply and
disconnect the fittings from the
flex hoses. Remove the filter
cartridges from both supplies.
Clean all debris from the filter
screens and reinstall the
screens, and reinstall the filter
cartridges.
E. The
aerator is
plugged.
E. Remove the aerator and clean.
For calcium/mineral deposits,
soak the plastic insert in a 50:50
mix of water and vinegar. Soak
only the plastic insert.
1025498-5-H 20 Kohler Co.