Kohler 8002A Plumbing Product User Manual


 
5
1067580-AN2-D 14/11/11
Finish the Installation
1. With the ribs of the sprayhead facing up,
attach the sprayhead to the waterway.
2. Using a 3/16” hexagonal wrench, fit
the sprayhead to the waterway with the
two securing screws (supplied). Do not
overtighten.
3. Check the sprayhead for upward and
downward movement and that is sits
squarely within the concealing plate.
4. Place the nozzle membrane over the
sprayhead.
5. Align the long edge of the membrane
with the hinge ribs (horizontal).
Note! For optimum performance make
sure that the membrane is applied
evenly.
6. Applying pressure evenly, press the
membrane seal into the sprayhead
groove.
7. Tilt the sprayhead downward so the ribs
on top of the sprayhead are exposed.
8. Insert the grooves of the sprayface over
the ribs of the sprayhead.
9. Press the sprayface down to cover the
sprayhead, as illustrated.
10. Tilt the sprayhead upwards to expose
the setscrew holes on the bottom of the
sprayhead.
Important! The setscrews must be ush
with the edge of the sprayface frame. If
the setscrews protrude outside of the
sprayface frame, product damage will
occur.
11. Using a 5/64” hexagonal wrench, turn
the setscrews anti-clockwise until they
are flush with the edge of
the sprayface
frame.
Sprayface
Ribs
Ribs
Groove
Finished Wall
Setscrews
Sprayhead
Waterway
Securing Screws
Attach the Sprayhead
Nozzle
Membrane
Attach the Sprayface