Install the Finished Wall
1. Finish the wall, leaving the cutout 102
to 108 mm square.
2. Make sure that the dimension from the
front face of the elbow or tee to the
surface of the finished wall is a minimum
of 57 mm.
3. Thread the nipple into the elbow or tee
and hand tighten.
4. Measure the distance from the end of
the nipple to the surface of the finished
wall. Make sure that it is between 38
and 44 mm. If necessary cut the nipple
to the required length.
5. Remove the nipple and apply thread
sealant to the ends of the nipple.
6. Reinstall the nipple to the elbow or
tee.
7. Turn obn the water supply and flush out
the supply pipes.
Install the Waterway
1. Install the concealing plate into the
rough opening. The double ribs of the
leak shield should be facing up.
2. If the leak shield makes contact with the
elbow enlarge the hole in the back of the
leak shield to 32 mm.
3. Thread the adapter onto the nipple using
a 7/16” hexagonal wrench.
Important! be careful not to damage
the flow adapter. The concealing plate
should fit loosely at this point.
4. Align the groove in the waterway with
the double ribs on the leak shield.
5. Press the waterway into place over the
adapter.
6. Secure the waterway to the adapter with
the screw provided.
7. Make sure that the concealing plate
does not turn and is not loose.
Important! If the concealing plate is still
loose at this point shorten the nipple.
102 to 108 mm
102 to 108 mm
102 to 108 mm
Cutout
Nipple
Tee (or Elbow)
Finished Wall
Cutout
57 mm Min
7/16" Hex Wrench
Leak Shield
Concealing Plate
Adapter
Waterway
Screw