IMPORTANT INSTRUCTIONS
WARNING: When using electrical products, basic precautions should always be followed,
including the following:
DANGER: Risk of electric shock. Grounding is required. Connect only to circuits protected by a
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD).
WARNING: Risk of electric shock. A qualified service representative and a licensed electrician
must install this product and route all electrical wiring for the product. Improper installation will
create an electrical hazard and may not comply with local building and electrical codes.
WARNING: Risk of electric shock. Disconnect power before performing any maintenance. When
disconnected, the product will no longer be electrically live, which will eliminate the risk of electric
shock.
WARNING: Risk of injury or property damage. Please read all instructions thoroughly before
beginning installation.
NOTICE: Follow all plumbing, electrical and building codes.
NOTICE: Provide generous, unrestricted service access to the valve and interface. This access must be
located immediately next to the valve. Refer to the roughing in information.
Specifications
Pressures
Maximum Static Pressure 125 psi, 862 kPa, 8.6 bar
Supply Pressure Differential* Max 5 psi, 34.5 kPa, 0.34 bar (Equal pressures recommended.)
Minimum Flow Rate 1.6 gpm (Less than 72 psi dynamic pressure.)
6 lpm (Less than 500 kPa maintaining pressure.)
2.1 gpm (Greater than 72 psi dynamic pressure.)
8 lpm (Greater than 500 kPa maintaining pressure.)
Temperatures
Programmable Temperature Max 120°F (49°C) Min 79°F (26°C) Full cold may also be selected.
Default Temperature at Start-up 102°F (39°C)
Minimum Mixed Temperature
Differential from Hot Supply
3.6°F (2°C)
Optimum Thermostatic Control Range 86°F (30°C) to 120°F (49°C)
Temperature Stability at Recommended
Supply Conditions
+/- 1.6°F (1°C)
Ambient Temperature Greater than 34°F (1°C), Max 104°F (40°C)
Maximum Relative Humidity 95% non-condensing
Electrical
Electrical Service 100-240 VAC, 50-60 Hz, 1.5 A
User Interface Cable Length (supplied) 30 ft (9.14 m)
* In commercial applications where there is a large difference in hot and cold supply pressures or frequent
fluctuation in either supply line is anticipated, it is strongly recommended that pressure regulators be
installed.
Thank You For Choosing Kohler Company
Thank you for choosing Kohler Company. Your Kohler Company product reflects the true passion for design,
craftsmanship, artistry, and innovation Kohler Company stands for. We are confident its dependability and
beauty will surpass your highest expectations, satisfying you for years to come.
All information in this guide is based upon the latest product information available at the time of
1043183-5-D 2 Kohler Co.