13. REGULATOR ADJUSTMENT KNOB
FOR UMBILICAL PRESSURE (H)
The regulator Adjustment Knob (H) allows the
operator to adjust the umbilical pressure within a
range of 115 psi to 225 psi (8-15.5 bars). Incoming
high pressure air from the ‘ORANGE” or “BLUE”
supply is reduced by the internal regulator. The
Adjustment Knob controls the regulator. Turning the
Knob clockwise decreases the umbilical pressure;
counterclockwise increases it.
14. OUTLET MANIFOLD INCLUDING
DIVER’S UMBILICAL FITTINGS (G)
The “WHITE DIVER” and “RED DIVER” air
supply hoses are connected to the KMACS 5 at the
manifold (G). The fittings coming out of the KMACS
5 are male #6 JIC (3/8”, 37°) flared fittings. The
diver’s air supply hoses must have matching female
#6 JIC flared fittings with swivel nuts.
The “WHITE DIVER” and “RED DIVER” pneumo-
fathometer hoses are also connected to the KMACS
5 at the manifold (G). The fittings coming out of
the KMACS 5 are male #4 JIC ( 1/4”, 37°) flared
fittings. The diver’s pneumofathometer hoses must
have matching female #4 JIC (1/4”, 37°) flared fit-
tings with swivel nuts.
15. PNEUMO VALVE KNOB, WHITE DIVER
(O)
The Pneumo Valve Knob, White Diver turns on and
off the air supply to the “WHITE” pneumofathometer
system.
16. PNEUMO VALVE KNOB, RED DIVER
(D)
The Pneumo Valve Knob, Red Diver turns on and
off the air supply to the “RED” pneumofathometer
system.
17. O-RING SEAL (U)
The O-ring seal helps keep dust and moisture out of
the KMACS 5 when the case is closed. The O-ring
seal is not pressure proof, however, and the KMACS
5 case will flood if the box is submerged.
18. COMMUNICATOR PANEL (V)
The diver’s electronic communicator (R) is attached
to the communicator panel. The battery for the com-
municator is located behind this panel.
19. COMMUNICATOR (R)
The MK3-KMDSI communicator is a standard open
circuit/round robin diver’s communicator, which
functions like a telephone. It can also be used as
a 2 wire, “push-to-talk” system. It is connected to
the diver’s umbilicals by “banana plug” fittings on
the communicator. The communicator is mounted
on the communicator panel. You should read and
understand the accompanying radio operations
manual supplied with the unit before using the
unit. Improper use or connections could damage
the radio.
CAUTION: Never connect the charger during
a dive or when anyone is in contact with
connected equipment. Although electrical
shock danger is remote, connection of the
recharging cord should only be done when
the KMACS 5 is not in use.