Kidde KN-COSM-B Smoke Alarm User Manual


 
CAUTION: This alarm will only indicate the presence
of carbon monoxide gas at the sensor. Carbon
monoxide gas may be present in other areas.
Individuals with medical problems may consider using
warning devices which provide audible and visual signals
for carbon monoxide concentrations under 30 ppm.
Step 1
Installing Batteries:
Batteries were not installed at the factory and must
be installed for the unit to operate! Install the three (3)
AA batteries in the back of the Smoke/CO Alarm.
The mounting plate must be removed from the
back of the unit to install batteries.To remove,hold
the mounting plate and twist counterclockwise (left).
The battery polarity markings on the bottom of the
battery compartment must be adhered to.
Batteries must be installed in the sequence shown.If
batteries seem difficult to install,they’re not being
installed in the proper sequence.
Smoke/CO Alarm will not engage to bracket unless
all three batteries are installed.Removal of any or all
batteries will render the Smoke/CO Alarm inoperative!
3
2
1
WARNING:
BATTERIES
MISSING
INSTALL
LAST
INSTALL
SECOND
INSTALL
FIRST
+
+
+
After the batteries are correctly installed the unit
will beep once and the red LED light will flash.
After 20-30 seconds the green LED light will flash
indicating the unit is now operational.
CAUTION: Your Smoke/CO Alarm is sealed and
the cover is NOT removable!
Step 2
Installation Instructions:
IMPORTANT: THIS ALARM MUST BE MOUNTED ON
A CEILING OR WALL. IT WAS NOT DESIGNED FOR
USE AS A TABLETOP DEVICE! INSTALL ONLY AS
DETAILED!
A. Recommended Installation Locations:
Kidde Safety recommends the installation of a
Smoke/CO Alarm in the following locations. For
maximum protection we suggest an alarm be installed
on each level of a multilevel home,including every
bedroom,hallways,finished attics and basements.Put
alarms at both ends of bedroom,hallway or large room
if hallway or room is more than 30ft.(9.1m) long.If you
have only one alarm,ensure it is placed in the hallway
outside of the main sleeping area,or in the main bed-
room. Verify the alarm can be heard in all sleeping
areas.
Locate an alarm in every room where someone sleeps
with the door closed.The closed door may prevent the
alarm from waking the sleeper.Smoke,heat and com-
bustion products rise to the ceiling and spread
horizontally. Mounting the alarm on the ceiling in the
center of the room places it closest to all points in the
room.Ceiling mounting is preferred in ordinary residen-
tial construction.When mounting an alarm on the
Operating/Installation Instructions
Operating/Installation Instructions
98
Batteries Must Be Installed in Order Shown Below:
Install
First
Install
Second
Install
Last
3
2
1
INSTALL
THIRD
INSTALL
SECOND
INSTALL
FIRST
WARNING:
BATTERIES
HAVE BEEN
REMOVED
AA
Battery
AA
Battery
AA
Battery
1.
2.
3.
1.
2.
3.