Kidde KN-COPP-3-RC Carbon Monoxide Alarm User Manual


 
DC Powered in Battery Backup Operation
If at any time you test the alarm and it does not perform as described, have it replaced immediately.
Handling
• Do not use the battery for a purpose other than for the alarm it is
specified.
Do not recharge the battery using any charging circuit other than the
one provided in the alarm. A recharging operation under non-
conforming recharging conditions can cause electrolyte leakage,
overheating, smoke emission, bulging/bursting and/or ignition.
• Do not discard the battery into fire or heat it under any circumstances.
Otherwise, it may cause the battery to explode. Do not connect
the battery to an electrical outlet.
• Do not connect the positive and negative terminals of the bat-
tery with any conductor such as metal wires. Do not store the
battery or transport it together with any metal objects.
Display Readings
“0” or CO
concentration
and “Lb” dis-
played once
every 60 sec-
onds, flash-
ing dot every
second.
1 “chirp” every
15 seconds
Battery conserve
mode, sensing
for CO.
Battery is partial-
ly discharged,
after 5 minutes
of operation on
battery backup.
Confirm battery
connection is
fullyseated &
oriented prop-
erly. Connect to
AC power to
fully charge
battery. Contact
Kidde customer
service if condi-
tion continues.
Flashing dot
once every
60 seconds.
1 “chirp”
every 60 sec-
onds
Unit in trouble
alarm. Mode will
continue for
approximately 7
hours. WILL
NOT DETECT
CO.
Operation on
battery backup
and battery is
fully dis-
charged.
Confirm battery
connection is
fullyseated &
oriented prop-
erly. Connect to
AC power to
fully charge
battery. Contact
Kidde customer
service if condi-
tion continues.
None. None. Unit is not
operational.
WILL NOT
DETECT CO.
Battery discon-
nected or miss-
ing.
Confirm battery
connection is
fullyseated &
oriented proper-
ly. Connect to
AC power to
fully charge
battery. Contact
Kidde customer
service if condi-
tion continues.
Li-Ion Battery Handling Precautions
28
Display Shows Alarm Sound Unit Status Unit Condition Recommended
Action