Kidde KN-COPP-3 Carbon Monoxide Alarm User Manual


 
24
Small amounts of water leaking from the base of the chimney, vent or flue pipe.
Rust on the portion of the vent pipe visible from outside your home.
The absence of a draft in your chimney (indicating blockage).
Fallen soot from the fireplace chimney.
Loose, damaged or discolored bricks on your chimney.
Clues You Cannot See...
Internal appliance damage or malfunctioning components
Improper burner adjustment
Hidden blockage or damage in chimneys
The maximum allowable concentration for
continuous exposure for healthy adults in any
8-hour period, according to OSHA*.
Slight headache, fatigue, dizziness, nausea
after 2-3 hours.
Frontal headaches within 1-2 hours, life
threatening after 3 hours.
Dizziness, nausea and convulsions within 45
minutes. Unconsciousness within 2 hours. Death
within 2-3 hours.
Headache, dizziness and nausea within 20
minutes. Death within 1 hour.
Headache, dizziness and nausea within 5-10
minutes. Death within 25-30 minutes.
Headache, dizziness and nausea within 1-2
minutes. Death within 10-15 minutes.
Death within 1-3 minutes.
50 ppm
200 ppm
400 ppm
800 ppm
1,600 ppm
3,200 ppm
6,400 ppm
12,800 ppm
Reminder: This chart relates to the exposure of healthy adults.
Concentration
of CO in the Air
(ppm = parts per million)
Approximate Inhalation Time and Symptoms Developed
Understand the Effects of Carbon Monoxide Exposure:
* Occupational Safety and Health Administration
Carbon Monoxide Safety