Installation
Receptacle Wiring
Receptacle wiring must be of adequate size for unit.
Refer to unit identification plate for exact power
requirements. Power requirements can also be
determined by the type of plug on unit. See Table 1 on
preceding page. Minimum size of wiring, based on
power requirements, is:
Units up to 20 amps: 12 gauge
20-30 amp units: 10 gauge
Use copper wire only. It is owner's responsibilityto
provide proper and adequate receptacle wiring that
conforms to all applicable codes. All wiring should be
installed by a qualified electrician.
Window Installationn7000 and 9000 Btu
Units (Models 78079, 70089)
I CAUTION I
To avoid risk of personal injury,property damage, or
product damage due to weight of device and sharp
edges that may be exposed:
Air conditioners covered in this manual pose an
excessive weight hazard. Two or more people are
needed to move and install unit. To prevent injury
or strain, use proper lifting and carrying methods.
Carefully inspect locationwhere air conditioner
will be installed. Be sure itwill support weight of
unitfor extended period of time,
Handle air conditioner with care. Wear protective
gloves whenever liftingor carrying unit. AVOID
sharp metal fins on front and rear coils.
Make sure air conditioner does notfall dudng
installation.
Required Tools and Equipment
Tight-fitting gloves
Standard screwddver
Phillips screwdriver
Pliers
Sharp knife
Carpenters' level
3/8"open-end wrench or adjustable wrench
1/4"hex socket and ratchet
Tape measure
Electdc drill
1/8"drill bit
Installation Kit Parts
Window installation kit contains the following parts. Be
sure all parts are included before starting installation. If
parts are missing, contact Sears.
NOTE: Parts are listed in the order used and are
illustrated in Figure 3.
Item #
A
B
C
D
E
F
G
Description
Window sill gasket (½" x ¼")
1¼" adjusting foot
Support bracket
%" hex-head screw
Sash bracket
%" Phillips screw
Window seal stdp (3A"x 1½")
Quantity
40"
1
1
3
1
3
40"
Figure 3. Window Installation Kit Parts