A. TROUBLESHOOTING
AUTOMATIC ELECTRONIC DIAGNOSTICS
The faceplate timer (PWA) computer has a self-
diagnostic function for the electrical system, except
for input power and water meter. The computer
monitors electronic components [ C _
and circuits for correct opera- I_l I- [
tion. If a malfunction occurs, an
error code appears in the face-
plate display.
The chart below shows the error codes that could
appear, and the possible defects for each code.
While an error code appears in the displa3_ all face
plate buttons are inoperable except the SELECT but-
ton. SELECT remains operational so the service per-
son can make the MANUAL INITIATED ELEC-
TRONIC DIAGNOSTICS (below) to further isolate
the defect, and check the water meter.
CODE
Err1, Err3,
Err4
Err5
POSSIBLE DEFECT
MOST LIKELY ._ _, LESS LIKELY
motor inoperative / wiring harness or connection to switch / position switch / valve defect causing
hiqh torque
faceplate timer (PWA)
PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE: 1. Unplug transformer 2. Correct defect 3. Plug
in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.
MANUAL INITIATED ELECTRONICS
DIAGNOSTICS
_To enter diagnostics, press the SELECT button
and hold for three seconds.
You will see the following display, showing valve
cycle position, position switch status (open or
closed), and turbine operation.
valve position indicator
indicator (open)
turbine count (water
flowing) _1.
! 1'"J
i ---:
turbine count (no
water flowing)
TURBINE OPERATION: If no water is flowing
through the softener, the turbine indicator displays
three zeros. When water is flowing, the flow bar
scrolls across the display, and a 000 to 140 count re-
peats for each gallon of water passing through the
turbine. To check for positive operation of the tur-
bine if zeros are shown, open a nearby soft water
faucet and observe the turbine count and flow bar.
If you don't get a reading in the display, with faucet
open, pull the sensor from the valve outlet port.
Pass a small magnet back and forth in front of the
sensor. You should get a reading in the display. If
you get a reading, unhook the in and out plumbing
and check the turbine for binding.
U
POSITION
SWITCH
SENSOR
VALVE
OUTLET
RBINE
SUPPORT AND
SHAFT
POSITION SWITCH STATUS: With the valve in ser-
vice, or any of the recharge cycles, the switch indica-
tor will show open _x._. While the valve is rotating
from 1 position to another, the indicator will show
the switch closed -,-,-. A defect is probable if indica-
tions vary from this pattern.