A. TROUBLESHOOTING
WIRING SCHEMATIC
<
Transformer
<
Turbine
Sensor
|
BACK OF TIMER |
t
grn
brn _NC
NO
Position
Switch
valve
motor
FACEPLATE f
UlbeSuf1200
TONleNT 1_800-426-9345
N_CHARG_ _Ken_r_feW_t_t com
_ow
LOW
Keep this manual with your water softener. If repairs are needed, the service technician must have
the information on the following 8 pages. For telephone assistance, call toll free, 1-800-426-9345.
ALWAYS MAKE THESE INITIAL CHECKS FIRST
i Does the time display show the correct time of
day?
--If display is blank, check power source to the
softener.
--If time is flashing, power was off for over 24
hours. The softener resumes normal operation
but regenerations occur at the wrong time.
- -If an error code (Example: Err3) shows in the
faceplate display, go to AUTOMATIC ELEC-
TRONIC DIAGNOSTICS, page 5-2.
i Plumbing bypass valve(s) must be fully in ser-
vice position.
i The inlet and outlet pipes must connect to the
softener inlet and outlet respectively.
His the transformer plugged into a "live",
grounded wall outlet, and the power cable fas-
tened securely?
The valve drain hose must be free of kinks and
sharp bends, and not elevated over 8 ft. above the
floor.
emove the top cover and salt tank cover.
_ Is there salt in the storage tank?
Is the brine tubing connected? Brine tubing con-
nects to nozzle venturi and brine valve assembly.
(See page 6-3, key #83)
I Is the brine valve float set right? (See page 5-4).
Press the SELECT button two times to display
the hardness setting. Be sure it is the correct set-
ting for the household's water supply. (Make a
hardness test of the raw water and compare with
the hardness setting. Also test a soft water sam-
ple to verify if a problem exists.) Press the SE-
LECT button twice more to return to present time
in the display.
If you do not find the problem after making initial
checks, do the MANUAL INITIATED ELEC-
TRONIC DIAGNOSTICS, and the MANUAL AD-
VANCE REGENERATION CHECK.
5-1