Specifications
FIG. 58
Questions? Call The Kenmore Water Line 1-800-426-9345
Intermittent flow rate does not represent the maximum service flow rate used for determining the soften-
ers rated capacity and efficiency. Continuous operation at flow rates greater than the service flow rate
may affect capacity and efficiency performance.
These systems conform to NSF / ANSI 44 for the specific performance claims as verified and substantiat-
ed by test data.
The efficiency rating is only valid at the minimum stated salt dosage. These softeners were efficiency
rated acocording to NSF / ANSI Standard 44.
OTHER SPECIFICATIONS MODEL 38376 MODEL 39376
Type of ion exchange material (resin) high capacity high capacity
Amount of resin (cu. ft.) 1.05 1.05
Rated Softening Capacity (Grains @ Pounds Salt Dose)
11,200 @ 2.2
30,000 @ 8.3
37,900 @ 14.3
11,200 @ 2.2
30,000 @ 8.3
37,900 @ 14.3
Efficiency Rating (Grains / Pound of Salt @ Minimum Salt Dose) 5070 @ 2.2 5070 @ 2.2
Rated Service Flow Rate (gpm) 9.0 9.0
Pressure Drop at Rated Service Flow Rate (psi) 12 12
Intermittent Flow @ 15 psi (gpm) 10.4 10.4
Max. Drain Flow Rate (gpm) 2.0 2.0