Kenmore 625.34859 Water System User Manual


 
SERVICE TECH. INFORMATION
SECTION 5
20
5A. TROUBLESHOOTING
Keep this manual with your water softener. If repairs are needed, the service technician must have the informaĆ
tion on the following 8 pages. For telephone assistance, call toll free, 1-800-426-9345.
WIRING SCHEMATIC
Motor, 24VAC
24VAC
Transformer
GND
OUT
+5
NC
NO
BACK OF TIMER
(PWA)
AC INPUT
Turbine
Sensor
Position
Switch
MOTOR
grn
brn
POS / TURBINE
SELECT
ON/OFF
HOLD
RECHARGE TONIGHT
RECHARGE NOW
Deluxe Demand Water Softener
Sears Water Line
for Customer Assistance
1–800–426–9345
with Dual Segment Electronic Display
SALT
LEVEL
ADJUST
SIGNAL
LIGHT
ADJUST
SALT
LEVEL
SIGNAL
LEVEL
LOW
SALT
ALWAYS MAKE THESE INITIAL CHECKS FIRST
1. Does the time display show the correct time of day?
--If display is blank, check power source to the softĆ
ener.
--If time is flashing, power was off for over 24 hours. The
softener resumes normal operation but regenerations
occur at the wrong time.
--If an error code (Example: Err3) shows in the face plate
display, go to AUTOMATIC ELECTRONIC DIAGNOSĆ
TICS.
2. Plumbing bypass valve(s) must be in Full Service
position.
3. The inlet and outlet pipes must connect to the softener
inlet and outlet respectively.
4. Is the transformer plugged into a live", grounded wall
outlet, and the power cable fastened securely?
5. The valve drain hose must be free of kinks and sharp
bends, and not elevated over 8 ft. above the floor.
REMOVE THE TOP COVER AND SALT TANK COVER
6. Is there salt in the storage tank?
7. Is the brine tubing connected? (See water flow
diagrams).
8. Is the brine valve float set right? (See page 23).
9. Press the SELECT button 2 times to display the hardness
setting. Be sure it is the correct setting for the
household's water supply. (Make a hardness test of the
raw water and compare with the hardness setting. Also
test a soft water sample to verify if a problem exists.)
Press the SELECT button twice more to return to
present time in the display.
If you do not find the problem after making initial checks,
do the MANUAL INITIATED ELECTRONIC DIAGNOSTICS,
and the MANUAL ADVANCE REGENERATION CHECK.