Kenmore 625.348420 Water System User Manual


 
WATER SOFTENER START-UP
SECTION 1
7
1C. PROGRAM THE TIMER
2. SET WATER HARDNESS NUMBER:
Press the SELECT button once to display 15
(flashing) and HARDNESS.
The grains per gallon (gpg) hardĆ
ness of your water supply is on
your water analysis report. Be sure
to enter water test results on page
2, for future reference.
NOTE:
If your water supply contains iron, compensate for it
by adding to the water hardness number. For
example, assume your water is 15 gpg hard and
contains 2 ppm iron. Add 5 to the hardness number
for each 1 ppm of iron. In this example, you would
use 25 for your hardness number.
15 gpg hardness
2 ppm iron x 5 = 10 +10
(times) 25 HARDNESS NUMBER
Press the UP/DOWN buttons to set your
water hardness number in the display. The DOWN
button moves the display to 1. The UP button moves
the display to the highest setting (see maximum
setting for your model in the specifications).
NOTE:
Each press of the UP/DOWN button changes the
display by 1 between 1 and 25. Between 25 and the
highest number, the display changes 5 at a time25,
30, 35, etc. Continuous pressure on the UP or DOWN
button changes the display twice each second.
3. SET RECHARGE (REGENERATION) TIME:
Press the SELECT button once to display 2:00 AM
(flashing) and RECHARGE TIME.
At the 2:00 AM RECHARGE TIME
setting, the softener begins regenĆ
eration (see pages 11 and 12) at
2:00 AM, ending no later than 4:00
AM. This is a good time in most
households because water is not
being used (see AUTOMATIC BYĆ
PASS, page 13).
If a different RECHARGE TIME setting would be
better for your household, do the following.
Press the UP/DOWN buttons to set the
desired RECHARGE starting hour. Be sure to observe
the AMĆPM as you did when setting the time of day.
NOTE:
Each press of the UP/DOWN buttons changes the
display 1 hour. Continuous pressure on the UP or
DOWN button changes the display twice each
second.
Press the SELECT button once again, to return
the present time (steady) of day and RECHARGE
TONIGHT in the display.
IF YOU NEED HELP PROGRAMMING THE TIMER, CALL TOLL FREE, NUMBER 1-800- 426- 9345.