OBSERVE ALL LOCAL CODES AND
ORDINANCES.
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD
GROUND PRONG.
ELECTRICAL GROUND IS REQUIRED ON
THIS APPLIANCE.
208!230-volt 60 Hz and 115-volt 60 Hz, AC
only, 15A fused and properly grounded
electrical supply is required. A time delay fuse
or time delay circuit breaker is recommended.
Use a dedicated circuit, serving only this
appliance.
DO NOT USE AN EXTENSION CORD.
RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance must
be grounded. This appliance has a power
supply cord with a 3-prong grounding plug. To
minimize possible shock hazard, the cord must
be plugged intoe mating grounding type wall
receptacle and grounded in accordance with
the National Electrical Code (ANSI/NFPA 70)
latest edition and all local codes and
ordinances. If a mating wall receptacle is not
available, it isthe personal responsibility and
obligation of the customer to have a properly
grounded 3-prong wall receptacle installed by a
qualified electrician.
115V-
d
230V-
Power cord may include a current interrupter
device. A test and reset button is provided on the
plug case. The device should be tested on a
periodic basis by first pressing the TEST button
and then the RESET button. If the TEST button
does not trip or ifthe RESET button will not stay
engaged, discontinue use of the air conditioner and
contact a qualified service technician.
NOTE; The shape may be different accordingto itsmodel
Use Wail Receptacle Power Supply
Standard125V,
3-wiregrounding
receptacle rated
15A,125VAC
Standard 250V,
3-wi_ g_unding
receptacle rated
15A, 25aVAC
Use 15 AMP, time
delay fuse or 15 AMP,
circuit breaker,
Standard 250V,
3_wire grounding Use 20 AMP. time
receptacle rated delay fuse or 20 AMP,
20A, 25av AC circuit breaker,
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
3-pron_ _G!
grounding
plug
Reset_
Test
Power prong
supply
cord
3-pron_
receptacle
(208/230-volt 60 Hz)
(115-volt 60 Hz)
-4-