Kenmore 580.5145 Dehumidifier User Manual


 
,_ _Possuble Causes >_ _ . ._,wnat- o Do -- _ '_,,_._.
Problem<..:i_, v,,=_ ,-_.,--._-_m,_ - ,_ " -,,_:,_,_ ...... ..,r,-'_.,,_ ' "
Dehumidifier The dehumidifier power Make sure the dehumidifier plug is pushed
does not start cord is unplugged completely into the outlet.
The fuse is blown or circuit Check the house fuse or circuit breaker box
breaker is tripped, and replace the fuse or reset the breaker
Water bucket is full The dehumidtfier automatically turns off
when th_s occurs Empty the bucket.
Bucket is not installed. Make sure a bucket in the right place
Dehumidifier Did not allow enough time When first installed, allow at least 3 or 4
does not dry the to remove the moisture, days to maintain the desired dryness.
air as it should Airflow is restricted. Make sure there are no curtains, blinds or
furniture blocking the front or back of the
dehumidifier.
The Humidity Control may o Press the O Humidity Control button to
not be set low Humidity. lower the humidity.
Doors and windows may Check that all doors, windows and other
not be closed tightly, openings are securely closed.
Clothesdryermaybeblowing Install the dehumidifier away from the dryer.
moisture-ladenairIntotheroom. The dryer should be vented to the outside.
Room temperature is too The unit will not operate satisfactorily if the
low. room temperature is below 65°F. (18°C.)
Area to be dehumidified is • Check with your dealer to see if the capacity
Dehumidifier runs too large, is adequate
too much
Doorsandwindowsareopen. Close all doors and windows to the outside.
Dehumidifier has been This is normal. Frost will usually disappear
Frost appears on recently turned on or room within 60 minutes.
the coils temperature is below 65°F.
(18°C.).
Fan noise Air is moving through the This is normal,
dehumidifier.
Bucket drain hose Check the hose if one is attached.
Water on floor connection may be loose.
Water bucket is not all the See the Removing and Emptyin_ The Water
way in. Bucket,
-10-