Kenmore 153.335943 Water Heater User Manual


 
Installation Instructions (cont'd)
USE WITHOUT POWER CORD (cont'd)
3. A standard _" conduit opening has been made in the water
heater junction box for the conduit connection.
4. Use wire nuts and connect the power supply wiring to the
wires inside the water heater's junction box.
5. The water heater must be electrically "grounded" by the
installer. A green ground screw has been provided on the
water heater's junction box. Connect ground wire to this
location. For complete grounding details and all allowable
exceptions, refer to local codes or in the absence of local
codes, with the latest edition of the National Electrical Code,
ANSI/NFPA 70.
6. Replace the wiring junction cover using the screw
provided.
WIRING DIAGRAM
_v
ON_F
SW;TCH
GA$
P_ESSURE
SWITCH
laOV GAS
SOLENOID HI.UMIT
SWlTC_ N_ N O
RESW_TCH
INOICATOn LIGHT I_V
o
Ain PRE$$UnE
sWITCH
F\
_ J
_ ItL_CK
HOT _ _
NEuTnAc _ITE
......111 [ ....I WXlTE
I
[
*_v GAS
SOLENOIO
Venting
AWARNING I
Toinsureproperventingofthisgas.firedwaterheater,the cor-
rect vent pipe diameter must be utilized.Any additionsof
other gas applianceson vent with this water heater will
[ adverseyaffecttheoperationofthe waterheater. I
The combustion and ventilation air flowmust not be obstructed.
AWARNING ]
The water heater with_stalled mustbe properly
ventedto a chimneywhichterminatesoutdoors.Never oper-I
ate thewaterheaterunlessit isventedto the outdoorsandhas
adequateairsupplyto avoidrisksofimproperoperation,explo-
sionor asphyxiation. ]
AWARNING
Obstructed or deterioratedventsystemsmaypresentaserious
healthrisk orasphyxation.
_,WARNING
The ventpipefrom the water heater must slopeupward I/4
nch per near foot.
All vent gases must be completely vented to the outdoors of the
structure (dwelling).
MIN. RISE I/4"
PERFOOT
16
I
_,WARNING and
Failureto haverequired clearancesbetweenwater heater
combustibe material wi resut n aErehazard.