23. Place screwdriver in slot “C”, see Figure 25. Depress and turn
counterclockwise (
) to stop. Control screw must be in “IN” position
for propane (LP) gas and in “OUT” position for natural gas. STOP!
Read label “For Your Safety” located on your water heater.
FIGURE 25.
24. Light pilot following the lighting and operating instructions on
the front surface of the heater.
25. Install outer door.
FUEL CONVERSION INSTRUCTIONS FROM
PROPANE (L.P.) GAS TO NATURAL GAS
For conversion of Propane (LP) gas to Natural gas follow the “Fuel
Conversion Instructions From Natural Gas to Propane (LP) Gas”
except in:
1. Step 14, remove LP gas pilot assembly.
2. Step 16, remove LP gas burner head.
3. Step 17, use burner ori ce marked “N”.
4. Step 18, use Natural gas burner head.
5. Step 20, use Natural gas pilot assembly.
6. Step 23, turn control screw in slot “C” in Figure 25
clockwise to stop. Screw must be in “OUT” position for
Natural gas.
See “Instruction Label” for ori ce sizes.
Maximum Supply Pressure:
10.5” W.C. for Natural Gas.
13” W.C. for Propane (L.P.) Gas.
Minimum Supply Pressure:
5” W.C. for Natural Gas.
11” W.C. for Propane (L.P.) Gas.