Kenmore 153.330652 Water Heater User Manual


 
Breathing Hazard - Carbon Monoxide Gas
High attiC:uric or;rice must _ nstalled for
epera_on above 2,000 feet (610 m),
Ceatact a qualified installer or service
agency
Breathing car_n monoxide eaa cause brain damage o[
d_ath Always read and understand instruction rna_ual
Water heaters covered in this manual have been tested and
approved for installation at elevations up to 2,000 feet (610
m) above sea level. For installation above 2,000 feet (610 m),
the water heater's Btu input should be reduced at the rate of
4 percent for each 1,000 feet (305 m) above sea level which
requires replacement of the burner orifice in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54. Contact your
local gas supplier for further information.
Failure to replace the standard orifice with the proper high
altitude orifice when installed at elevations above 2,000 feet
(610 m) could result in improper and inefficient operation of the
appliance, producing carbon monoxide gas inexcess of the safe
limits. This could result in serious injury or death. Contact your
local gas supplier for any specific changes that may be required
in your area.
Sediment Traps
Fire and Explosion Hazard
Contaminants in gas lines can
cause fire or explosion.
Clean all gas piping before
installation.
Install drip leg in accordance with
NFPA 54.
Contaminants in the gas lines may cause improper operation
of the gas control valve that may result in fire or explosion.
Before attaching the gas line be sure that all gas pipe is clean
on the inside. To trap any dirt or foreign material in the gas
supply line, a drip leg (sometimes called a sediment trap) must
be incorporated in the piping. The drip leg must be readily
accessible. Install in accordance with the Gas Piping section.
Refer to the current edition of the National Fuel Gas Code,
ANSI Z223.1/NFPA 54.
A sediment trap shall be installed as close to the inlet of the water
heater as practical at the time of water heater installation. The
sediment trap shall be either a tee fitting with a capped nipple
in the bottom outlet or other device recognized as an effective
sediment trap. If a tee fitting is used, it shall be installed in
conformance with one of the methods of installation, shown in
Figures 19 and 20.
i Fire and Explosion Hazard
Use joint compound or tape
compatible with propane,
Leak test before operating
heater.
Disconnect gas piping and
shut-off valve before pressure
testing system.
GROUND JOINT
UNION
(OPTIONAL)
3" MtN. t
(76.2 mm)
GAS CONTROL
Use pipejoint compound or Teflon tape marked as being resistant
to the action of petroleum (Propane [L.R]) gases.
The appliance and its gas connection must be leak tested before
placing the appliance in operation.
The appliance and its individual shutoff valve shall be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 pound per square inch (3.5 kPa). It shall be isolated from
the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 pound per
square inch (3.5 kPa).
Connecting the gas piping to the gas control valve of the water
heater can be accomplished by either of the two methods shown
in Figures 19 and 20.
®
TEFLON is a registeredtrademarkof E.I.Du Pont De Nemours and Company.
FIGURE 19. GAS PIPING WITH FLEXIBLE CONNECTOR.
GROUND JOINT I_
UNION II
(OPTIONAL) _ K PIPE
II ORtPLEG
(76.2 mm)_ U (SEDIMENTTRAP)
GAS CONTROL
VALVE
FIGURE 20. GAS PIPING WITH ALL
BLACK IRON PIPE TO GAS CONTROL.
17