Kenmore 153.330402 Water Heater User Manual


 
Troubleshooting Guide (cont'd)
Operational Conditions
HOT COLD WATERHEATER (3)
COLDWATER PRESSURE
INLETFITTING REDUCING
VALVEWITH
BY-PASS
EXPA(I)SIO N _'_
TANK __
PRESSUREGAUGE INLETCOLD
WATER
SHUTOFF
RECOMMENDED INSTALLATION
(VERTICAL MOUNTING)
SMELLY WATER
in each glasslined water heater there is installed at least one
anode rod (see parts section) for corrosion protection of the
tank. Certain water conditions will cause a reaction between this
rod and the water. The most common complaint associated with
the anode rod is one of a "rotten egg smell". This odor is derived
from hydrogen sulfide gas dissolved in the water. The smell is
the restllt of four factors which must all be present for the odor
to develop:
a. a concentration of sulfate in the supply water.
b. little or no dissolved oxygen in the water.
c. a sulfate reducing bacteria within the water heater. (This
harmless bacteria is non-toxic to humans.)
d. an excess of active hydrogen in the tank. This is caused by
the corrosion protective action of the anode.
WATER HEATER
COLD WATER
INLET FITTING
FLOOR,CEILING
JOIST,ETC.
Smelly water may be eliminated or reduced in some water heater
models by replacingthe anode(s) with one of lessactive material,
and then chlorinating the water heater tank and all hot water
lines. Contact Sears Service for further information concerning
an Anode Replacement Kit #9001453 and this Chlorination
Treatment.
HOT
STRAPPING
(,)
EXPANSION
(3)
PRESSURE
REDUCING INLETCOLD
VALVEWITH WATER
BY-PASS SHUTOFF
If the smelly water persists after the anode replacement and chlo-
rination treatment, we can only suggest that continuous chlori-
nation and filtering conditioning equipment he considered to
eliminate the water problem.
Do not remove the anode leaving the tank unprotected. By
doing so, all warranty on the water heater tank is voided.
"AIR" IN HOT WATER FAUCETS
PRESSUREGAUGE
ALTERNATE RECOMMENDED
INSTALLATION
(HORIZONTAL MOUNTING)
STRANGE SOUNDS
Possible noises due to expansion and contraction of some metal
parts during periods of heat-up and cool-down do not represent
harmful or dangerous conditions.
Condensation causes sizzling and popping with the burner area
during beating and coolln{_ periods and should be considered
normal. See Condensation section.
AWARNING
HYDROGEN GAS: Hydrogen gas can be produced in a hot
water system that hasnot been usedfor a long period of time
(generally two weeks or more). Hydrogen gas is extremely
flammable and explosive. To prevent the possibility of injury
under these conditions, we recommend the hot water faucet
be opened for several minutes at the kitchen sink before any
electrical applianceswhich are connected to the hot water sys-
tem are used (such as a dishwasher or washing machine). If
hydrogen gas is present, there will probably be an unusual
soundsimilar to air escapingthrough the pipeas the hot water
faucet is opened. There must be no smoking or open flame
near the faucetat the time it isopen.
23