ThankYouforpurchasinga Searswaterheater.Properly
instalbdandmaintained,it shouldgiveyouyearsoftrouble
freeservice.Itisstronglysuggestedthatthisnewwaterheater
beprofessionallyinstalled,contactthelocalSearsService
CenteroranySearsstore.Theywillarrangeforprompt,quality
installationbySearsauthorizedcontractors.
AbbreviationsFoundInThis{nstructionManual:
UL= UnderwritersLaboratoriesInc,
NEC= National Electrical Code
ANSI = American National Standards Institute
Read the "General Safety" section, page 3 of this manual
first and then the entire manual carefully. If you don't follow
the safety rules, the water heater wil! not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.
This manual contains instructions for the installation,
operation, and maintenance of this ebctric water heater. It
also contains warnings throughout the manual that you must
read and be aware of. Ai! warnings and all instructions are
essential to the proper operation of the water heater and
your safety. Since we cannot put everything on the first few
pages, READ THIS ENTIRE MANUAL BEFORE ATTEMPTING
TO INSTALL OR OPERATE THE WATER HEATER.
The installation must conform with the instructions in this
manual; electric company rules; and Local Codes, or in the
absence of Local Codes, with the current edition of the
NEC o National Electrical Code, NFPA 70. This publication
is availabb from your local government or public library or
electric company or by writing Underwriters Laboratories
Inc., 333 Pfingsten Road, Northbrook, IL 60062.
If after reading this manual you have any questions or do
not understand any portion of the instructions, call Sears
Service Center.
Carefully plan the place where you are going to put the water
heater. Correct electrical wiring and connections are very
important in preventing death from possible electrical shock
and fires.
Examine the location to ensure the water heater complbs with
the "Facts to Consider About the Location" section.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation procedures.
Instructions may be obtained from the California Office of the
State Architect, 400 P Street, Sacramento, CA 95814.
Massachusetts Code requires this water heater to be installed
in accordance with Massachusetts 248oCMR 2.00; State
Plumbing Code and 248-CMR 5.00. In the Commonwealth of
Massachusetts, this product must be installed by a licensed
plumber or gasfitter.
MODEL
NUMBER
153.329262
153.329263
153.329360
153.329361
153.329460
153.329481
153.329560
153.329561
153.329660
153.329681
153.329880
153.329861
TANK
CAPACITY
Gab Liters
38 144
30 114
40 151
55 208
66 250
80 303
DBMENSBONS
iN iNCHES (rnm)
DBA. HEIGHT
25 (635) 31.5 (800)
19 (483) 47 (1,194)
19 (483) 60 (1,524)
21.5 (546) 61 (1,549)
23 (584) 61 (1,549)
25 (635) 61.5 (1,562)
ELEMENT
RECOVERY RATE WATTAGE
GALS.PER HOUR @240 VOLTS
@90°F Rise UPPER LOWER
17.3 3800 3800
25.0 3800 5500
17.3 3800 3800
25.0 3800 5500
17.3 3800 3800
25.0 3800 5500
17.3 3800 3800
25.0 3800 5500
17.3 3800 3800
25.0 3800 5500
173 3800 3800
25.0 3800 5500
MINtMUM
WiRE SIZE*
{GAUGE)
12
10
12
10
12
10
12
10
12
10
12
10
MAXBMUM FUSE
OR qRCUr
BREAKER
SiZE (AMPS}
20
30
20
30
20
30
20
30
20
30
20
30
Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical
code.