Kenmore 152.329361 Water Heater User Manual


 
8,
g,
Clean the area around the element opening, Remove any
sediment from or around the element opening, inside the
tank,
If you are cleaning the element you have removed, do so by
scraping or soaking in vinegar or a deoliming solution,
Fire Hazard and
Electric Shock Hazard
* Do not use replacement elements with
any voltage other than shown on the
model rating plate.
Failureto usethe correct voltageshown
on the model rating platecould result in
death, serious bodily injury, or property
damage.
Replacement elements must (1) be the same voltage and (2)
no greater wattage than listed on the model rating plate affixed
to the water heater,
10. A new gasket should be used in all cases to prevent a
possible water leak, (See Element Gasket in the 'Parts
Order List " Chart). Place the new element gasket on the
thread side of the cleaned or new element and screw into
tank, securing tightly using an element wrench,
FIGURE 37.
11, Close the water heater drain valve by turning the handle to
the right (c!ockwise). The drain valve id on the lower front of
the water heater.
12. Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open when the
water heater is in use.
13. To insure complete filling of the tank, allow air to exit by
opening the nearest hot water faucet, Allow water to run
until a constant flow is obtained, This will let air out of the
water heater and the piping,
Improper installation and use may result
in property damage.
Fill tank with water before operation,
Never use this water heater unless it is completely full of water.
To prevent damage to the tank and heating element, the tank
must be filled with water. Water must flow from the hot water
faucet before turning 'ON" power.
14, Check element for water leaks. If leakage occurs, tighten
element or repeat steps 2 and 3> remove element and
reposition gasket. Then repeat steps 10 through 14.
15, Reconnect the two wires to the element and then check to
make sure the thermostat remains firmly against the
surface of the tank.
FIGURE 38.
16, Replace terminal cover on thermostat making sure that
the locking tabs on the terminal cover are in place,
/
UFT OUT TAB TO UNCUP
TERMINAL COVER
FROM THERMOSTAT
LOWER THERMOSTAT
WITHOUT HIGH LIMIT
UPPER AND LOWER
THERMOSTAT WITH
HiGH LIP_,IlT
FIGURE 39.
17, Place the insulation cap with handle back in place so that
it completely covers the thermostat and element.
i-1
21
FIGURE 40.